Vecto
III
User Manual
43
2.4.9
GPS
The female SMA port is used to interface an external powered (+3V3) GPS antenna to
the Vecto III. The built-in GPS is used to measure absolute time. The Vecto III locks its
internal clock to within 1µs from absolute time.
Figure 17: GPS antenna connector
2.4.10
Ethernet Ports
The device has 2 Gigabit Ethernet ports as depicted in Figure 18. The IP address of port
2 is fixed at 192.168.7.1. The device serves as a DHCP server for the network connected
to this port. The IP address of port 1 can be set using the Osprey Lite
TM
software (see
Osprey Lite
TM
User Manual).
Do not connect Ethernet port 2 to a network with an active
DHCP server, as this may cause the network to stop functioning
properly
The IP address of Ethernet port 2 is fixed at 192.168.7.1