14
Installation -
Metal Roof
STEP 10
Position the ventilator
top onto the top of the
varipitch.
The three mounting
points on the lower ring
align with the three
notches on the varipitch.
STEP 9
Check the varipitch level
again and ensure it is still
level across all directions.
Screw the varipitch to the
flashing with the three
screws provided at the
pre-drilled holes on the
varipitch.
Lock the varipitch by
screwing the fixing
clip into the lower half
with one of the screws
provided.
Fix with supplied screws
Lock Varipitch
Align
Apply sealant internally to the varipitch seam.
Do not seal the varipitch to the flashing.