11
Installation -
Metal Roof
STEP 3
Return the flashing to
the roof, positioning
it over the cutout.
Ensure that the top of
the flashing is slipped
under the ridge capping.
For lower pitched roofs,
turn up the top edge
of the flashing before
slipping under ridge
capping. This will help
prevent water ingress.
STEP 4
Using a soft rubber
hammer, carefully
work around the sides
and lower edge of the
flashing to form it into
the corrugations of the
metal sheeting profile.