background image

- 21 -

Uplink

Gain[dB]: 

Displays the status of the Uplink Gain.

Atten[dB]:

 Displays the Uplink Attenuation value.

ALC Atten[dB]: 

Displays the attenuation value of a strong signal in the initial stage when

unit is powered (Control unavailable).

ALC: 

This allows the user to toggle the Auto Level Control function on or off.

ALC Level[dBm]: 

Sets the unit’s maximum ALC output value.

Shutdown: 

This allows the user to toggle the HPA shutdown of the unit if the Downlink
output is higher than the user determined shutdown value.

Shutdown Level: 

This allows the user to input the maximum value at which the

unit will shutdown.

HPA: 

This allows the user to toggle the Uplink HPA on or off.

Uplink Status Mode

Uplink Control Mode

Summary of Contents for SMR-700/800

Page 1: ...CSI T51080 SP78 InstallationManual ...

Page 2: ......

Page 3: ...l Arrangement 7 Outline Drawing 8 Internal Arrangement 9 PSU 10 GUI Graphic User Interface 11 Program Introduction 11 GUI Setup 11 Open Serial Communication Port 15 Condition Check and Control 16 System Status Mode 17 Normal Mode 17 Alarm Status Mode 18 Power Status Mode 18 Isolation Status Mode 19 Downlink 20 Uplink 21 Frequency Information 22 Band Select 22 Shutdown Period 23 Control Send 23 Man...

Page 4: ......

Page 5: ... 6677 The serial number may be found on the label on the panel near the power connec tors Note this number below Retain this manual along with proof of purchase to serve as a permanent record of your purchase MODEL NUMBER SERIAL NUMBER DATE OF PURCHASE POINT OF SALE COMPANY Product Registration Information DISCLAIMER All information and statements contained herein are accurate to the best of the k...

Page 6: ... water Keep the unit clean and dust free during installation Do not place cables or tools in close proximity to the repeater that may damage it Do not wear jewelry watches or any type of metal accessories when installing the unit Check the installation site for hazardous conditions such as water covered floors or badly worn or damaged cables prior to installation Lifespan and performance of the re...

Page 7: ... LNA AGC Block Amplifies the low end signal coming from the antenna while minimizing noise Up Down Converter Block Made up of a Mixer and an IF SAW Filter It converts frequencies to different frequencies that utilize better filter performance HPA DRV AMP Block A power amplifier for the repeater s high output high gain and high linearity PLL Block Localizes signal for Up Down converting CPU Block C...

Page 8: ...requency Selectivity UL DL 40dBc _2MHz Gain UL DL 80dB _1 0dB Sub Band Balance UL DL _1 0dB Gain Adjustment Range UL DL 30dB 30dB _1dB 1dB Step ALC Range UL DL 25dB 25dB _1dB Pass Band Ripple UL DL _1 5dB Peak To Peak 3dB Linear Output Power UL DL 27dBm 3rd Order Intercept Point UL DL 42 5dBm 1dB Gain Compression UL DL 31dBm Input VSWR UL DL 2 1 Max Power Input w o Damage UL DL 10dBm Propagation D...

Page 9: ...RS232C Internal 9P D SUB female Alarm External 9P D SUB female Mounting Type Wall Mounting with 4 holes 2 holes on each side Enclosure Lock Key Lock Heat Dissipation Natural Convection Mechanical Specification Operating Temperature 10 C 50 C ambient 14 122F Storage Temperature 30 C 55 C ambient 22 130F Humidity 95 Environmental Specification o Parameters Specifications Remarks Parameters Specifica...

Page 10: ...orrect isolation problem Solid Off Solid This condition is the Shut Down Alarm signal received from cell tower is too strong more than AGC range GREEN RED RED Relocate DL antenna to reduce received signal strength Solid Off Blinking PLL Lock Detected Failure Alarm GREEN RED RED Blinking Off Off Repeater is non functional Contact Customer Service Center GREEN RED RED Alarm Interface High NO CC 1 NC...

Page 11: ... 7 Product Appearance External Arrangement ...

Page 12: ...Outline Drawing 8 ...

Page 13: ... 9 Internal Arrangement Power supply GUI Port Display LED CPU Board LED Holder RF Board ...

Page 14: ... 140VAC output Line Regulation Voltage 3 Normal operation 24V 2A 6V 2A Load Regulation output Voltage 3 Short Current Protection A decline in output voltage will be normalized 24V 100mVp p Ripple and Noise 6V 50mVp p Efficiency 70 Power Supply Specification Item Specifications Remarks The unit s Power Supply ...

Page 15: ...hecks and controls the operation of the control board for the SMR 700 800 This program will be communicated via the control board and RS 232C Port GUI Setup Begin the installation of the program with the file CSI SMR Setup exe Figure 1 Application program installation ...

Page 16: ...Figure 2 Program installation application When the screen in Figure 2 appears Click Next Decide which folder you wish to download into then click Next Figure 3 Program installation application 12 ...

Page 17: ... 13 Figure 4 Program installation application When ready to install program click Install Figure 5 Ongoing program installation application ...

Page 18: ...Figure 6 Program installation complete screen Click Finish when setup is complete Run Program CSI_SMR exe You should see the CSI Icon listed on your startup menu as seen above 14 ...

Page 19: ... 15 Open Serial Communication Port Select communication port on your PC then press OPEN to enable communication with repeater Indicates the status of communication with the repeater ...

Page 20: ...Checking status and control of the SMR 700 800 unit This screen indicates repeater status and control You may check each by clinking on the control buttons shown below Status Mode Control Mode 16 ...

Page 21: ...ature Indicates the inner temperature of repeater Note The SYSTEM pull down menu is not part of the Control Menu Normal Mode The System Status screen DL UL Offset Controls the power level of the Uplink based on the Downlink power level On Off Offset Level Controls the Uplink power level based on the Downlink power level and displays the difference between the two Status Mode Control Mode ...

Page 22: ...rm pull down menu is not part of the Control Menu Power Status Mode NetWork Output dBm Displays Downlink output NetWork iDEN Output dBm Displays Downlink output iDEN UL Output dBm Displays Uplink output Network RSSI dBm Displays the Downlink output NetWork iDEN RSSI dBm Displays the Downlink input iDEN Note The POWER pull down menu is not part of the Control Menu Alarm status Mode screen Power sta...

Page 23: ...ormed with the power on or off Isolation Recheck Checks Isolation without the power on Isolation Attenuation This allows control of the Isolation attenuation Note Neither the Isolation Check or Recheck will not indicate a change in power levels if the unit s own power has been switched off Isolation status Mode screen Isolation Control Mode screen ...

Page 24: ...vel dBm Sets the unit s maximum ALC output value ALC Offset This allows the user to toggle the Auto Level Control Offset on or off ALC Offset dB Sets the unit s minimum ALC output value Shutdown This allows the user to shutdown the unit if the downlink output is higher than the user determined shutdown value Shutdown Level This allows the user to input the maximum value at which the unit will shut...

Page 25: ...e user to toggle the Auto Level Control function on or off ALC Level dBm Sets the unit s maximum ALC output value Shutdown This allows the user to toggle the HPA shutdown of the unit if the Downlink output is higher than the user determined shutdown value Shutdown Level This allows the user to input the maximum value at which the unit will shutdown HPA This allows the user to toggle the Uplink HPA...

Page 26: ...1 MHz 50 KHz Steps Frequency Status Mode Frequency Control Mode Band Select Band 1 On Off Activates Band 1 Frequency Band 2 is deactivated Band 2 On Off Activates Band 2 Frequency Band 1 is deactivated Band Select Status Mode Band Select Control Mode 22 ...

Page 27: ... Allows the user to set the shutdown period duration Shutdown Status Mode Shutdown Control Mode Control Send Control Send When the unit is fully configured the settings can then be sent to the repeater by clicking on the CONTROL SEND button ...

Page 28: ...Management Mode Press Ctrl F10 while in Mode Status Control Mode to go into Management Mode Management Mode Screen 24 ...

Page 29: ... value of UL Out Click the appropriate LOAD button to display the following Compensation Temp Offset Allows the user to input a value for the repeater temperature offset Load This displays the temperature offset value Normal DL UL Offset This displays the value of DL UL Offset Load This allows the user to toggle the DL UL Offset display on or off Offset Level This displays and allows the user to s...

Page 30: ...tten This controls displays the attenuation value of the Downlink iDEN UL Atten This displays the attenuation value of the Uplink User Atten This controls displays the attenuation value of the Uplink ALC Atten This controls displays the attenuation value of the Uplink ALC Load Atten This configures the attenuation values in the repeater and updates the values displayed in the DL Atten UL Atten win...

Page 31: ...to user applied values Write This saves the most current version of the table to a txt format Read This displays the txt copy of the table on the screen The POWER TEMP Atten table displays the applied decibel value for NetWork RSSI iDEN RSSI UL Output It does not display A D values Offset Configure the unit s Offset values using the Offset table Temp Table andAttenuation Table is not used ...

Page 32: ...epeater and the PC Go This displays the comunications contents that have been suspended Stop This command stops the contents of the communications from scrolling Clear This deletes all communication contents being displayed Exit This command closes the debug window Always Top This sets the debug window to always display at the top of the window 28 ...

Page 33: ...status will be displayed The Download Complete message will open when the procedure is complete or an error message will be displayed Write the firmware file to the repeater Close This command closes the download window This feature is currently not used Feature will be included in the next production run Next perform the following steps Factory Settings Click on the Factory Set button in Manageme...

Page 34: ... 30 ...

Page 35: ...ity shall be paid by Buyer The provisions of this warranty shall be applicable with respect to any product which Seller replaces pursuant to it SELLER MAKES NO WARRANTY EXPRESS OR IMPLIED OTHER THAN AS SPECIFICALLY STATED ABOVE EXPRESSLY EXCLUDED ARE THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PURPOSE THE FOREGOING SHALL CONSTITUTE ALL OF SELLER S LIABILITY EXCEPT AS TO PATENT INFRIN...

Page 36: ...D960 1048 001 rev002 ...

Reviews: