Power Supply is malfunctioning
X
X
X
(inside repeater)
Blinking
Blinking
Blinking
Checking Isolation Status
GREEN
RED
RED
Solid
Off
Off
Normal Condition at Start up
GREEN
RED
RED
Solid
Off
Off
Insufficient distance (Isolation) exists between the DL
and UL Antennae. Remove power and re-install the DL
GREEN
RED
RED
and UL Antennae to correct isolation problem.
Solid
O f f
Solid
This condition is the Shut-Down Alarm: signal received
from cell tower is too strong (more than AGC range).
GREEN
RED
RED
Relocate DL antenna to reduce received signal strength.
Solid
O f f
Blinking
PLL Lock Detected Failure Alarm.
GREEN
RED
RED
Blinking
O f f
O f f
Repeater is non-functional. Contact
Customer Service Center.
GREEN
RED
RED
Alarm Interface
High
NO + CC
1 NC, 2 NO, 3 CC
L o w
NC + CC
Alarm Relay
- 6 -
Repeater Unit LED
Condition / Troubleshooting
Power
ISO
Alarm
Shutdown Signal
Relay Status
Remarks