background image

 

 

                                                                                                                                                     

SIGNATURE 2 SERIES 

                                                                                                                                         

Signature 2 Series 

Hydroxr VS

Installation / Operation

Manual

Summary of Contents for signature 2 hydroxr vs

Page 1: ...SIGNATURE 2 SERIES Signature 2 Series Hydroxr VS Installation Operation Manual ...

Page 2: ...Control Start Up Procedures Page 9 Utilizing Bluetooth Page 11 Master Programming Page 12 Powerhead Assembly Page 13 Valve Body Assembly Page 14 Manifold Breakdown Page 15 Bypass Assembly Page 16 Additional Information Page 17 Troubleshooting Page 18 Error Codes Page 18 ...

Page 3: ...removed from the filter by reversing the flow of water through the filter and running to drain Called Backwashing and last ing 10 minutes the process expands the mineral bed freeing the iron sulfur and turbidity which is then washed out of the filter to the drain It is important that the correct amount of water is available for the backwash cycle Check pump capaci ty to be certain water is availab...

Page 4: ...tem Filter Tank A level floor position ahead of piping into water heater Unit must be installed at least 10 ahead of the inlet to a water heater to prevent damage due to back up of hot water DO NOT install unit in an area of direct sunlight or where freezing temperatures may occur Installation 4 Note Caution should always be used in sizing filters Always choose a unit by first satisfying the Backw...

Page 5: ...ocedure Water Supply Connection and Bypass Valve To allow for HYDROXR VS Filter servicing a manual bypass valve have been installed at the factory The bypass valve allows raw water to be manually routed around the filter 1 Position HYDROXR VS Tank and Filter Tank at desired location for installation If a water softener is to be installed it should be positioned after the Filter Tank 2 The filter m...

Page 6: ...ed pump outlet tubing to air vent hose barb 2 Locate air compressor in close proximity to HYDROXR Aeration Tank A Connect the supplied tubing from compressor outlet to Aeration tank manifold inlet Do not connect to air vent hose bard 3 Rotate handle of the bypass valve to the bypass position across the bypass 4 Turn the main supply line on to restore water service to the home 5 OPEN nearest faucet...

Page 7: ... System 1 Make certain Signature Series 2 Control Valve is in SERVICE position 2 Slowly rotate inlet knob of the bypass valve to the SERVICE position parallel with plumbing 3 Open the nearest faucet to evacuate air from plumbing lines 4 Let faucet run until compressor and peroxide feed pump turn on Note Compressor and Peroxide Feed Pump will not start immediately If compressor and feed pump do not...

Page 8: ...9 96 100 Straight H2O2 84 This chart is an estimation only Actual solution strength and frequency stroke setting may differ Adjust feed pump frequency stroke setting and or solution strength to achieve 2 5 ppm residual H2O2 at the kitchen faucet It is for this reason that a minimum quantity of solution be mixed on initial start up until the actual solution strength can be determined Priming Peroxi...

Page 9: ...ever occur 3 Default setting is 6 days for filters 5 To Exit Main Menu press the Menu Enter button Note If no buttons are pressed for 60 seconds the Main Menu will be exited automatically 9 Control Start Up Procedures Final Checkout 1 Be certain that the bypass valve is in Service position and main valve is completely on 2 Check electrical supply to be certain the cord is connected to an uninterru...

Page 10: ...eturn and finish the cycle where it left off prior to the power interruption When used without battery back up during a power failure the unit stops at its current point in the regeneration position and then restarts at that point when the power is restored The time will be offset by the increment of time the unit was without power so it is necessary to reset the time of day on the unit No other s...

Page 11: ...r If the valve device is a BTLE valve and it has a password other than the default password the first time you connect to it the app will ask you to enter the password After entering it the first time you should not need to enter it again unless it changes 4 BTLE Valve devices can be updated by the App When the app is updated from the Google Play Store or the Apple App Store it may contain an upda...

Page 12: ...nge the digits with the Set Change button and accept with the Menu Enter button After the entire display flashes press the Menu Enter button to move to the next menu item 2 Regeneration Cycle Step Times Steps 1 2 3 Example 3 10 The next 4 displays set the duration of time in minutes for each backwash cycle step The step number which is currently modifiable is indicated on the far left of the displ...

Page 13: ...20001X005 1 8 Lower Front Base For Cover 20111X002 1 9 Motor 20016X006 1 10 Lower Back Base for Cover 20111X003 1 11 Valve Cover 20111X000 1 12 Piston Screw 20001X003 1 13 Screw SC10 3 14 Screw SC9 3 15 Piston Washer 20001X002 1 16 Washer Circuit Board 20111X014 1 17 Screw Motor SC2 1 21 Valve Hex Screw 20001X001 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 E M F Port is for softener flow meter conn...

Page 14: ...M PVC 20251X262 1 Flow Control Assy 6 0 GPM PVC 20251X263 1 Flow Control Assy 7 0 GPM PVC 20251X264 1 7 Drain Flow Fitting 90 º Elbow 1 2 NPT X 1 2 20251X255 1 8 Drain Retainer 20001X214 1 9 O Ring Brine Valve Cap Assembly 20001X230 1 10 O Ring Filter Plug Assembly 20001X229 1 11 10 24 X 1 Screw 20001X226 1 12 Injector Cap 20001X223 1 12A Filter Conversion Kit Incl 1 each 9 10 12 13 14 2 11 20001X...

Page 15: ...tion Part Number 1 1 4 Brass Hose Barb 65555X217 2 Vent Tube 3 4 OD X 1 4 ID X 12 65555X216 3 VS Manifold with O Ring 65555C007 4 Hydroxr Float Assembly 65555X223 5 Diffuser with Screws 65555X212 6 Manifold O Ring 65555X009 7 VS Check with 1 4 Tube X 1 4 NPT 68555X215 ...

Page 16: ...SIGNATURE 2 SERIES Bypass Assembly Ref Description Part Qty 1 Plastic Bypass Valve Assembly 20561X292 1 2 Bypass Valve 3 4 Stainless Steel 20561X270 1 Bypass Valve 1 Stainless Steel 20561X283 1 16 1 2 ...

Page 17: ...e powerhead mounting screws The entire powerhead assembly will now lift off easily 4 Remove piston retaining plate screws 5 Pull upward on end of piston yoke until assembly is out of valve 6 Inspect the inside of the valve to make sure that all spacers and seals are in place and that there is no foreign matter that would interfere with the valve operation 7 Take new piston assembly and push piston...

Page 18: ...backwash setting Backwash more frequently 5 Continuous Flow to Drain Foreign material in control valve Call dealer Clean valve and replace piston and seals Internal control leak Same as above Valve jammed in backwash brine or rapid rinse position Same as above Motor stopped or jammed Check for jammed piston Replace piston and seals Replace motor if motor is unresponsive Error Codes There are five ...

Page 19: ..._______________________________ ___________________________________________________________________________________ ___________________________________________________________________________________ ___________________________________________________________________________________ ___________________________________________________________________________________ ________________________________...

Page 20: ...tion resulting from abuse including freezing improper or negligent handling shipping by anyone If the unit has not always been operated within the factory calibrated temperature limits and at a water pressure not exceeding 125 psi oth er than CSI storage use operation accident or alteration lightning flooding or other environmental conditions To any failure or malfunction resulting from failure to...

Page 21: ...SIGNATURE 2 SERIES ...

Page 22: ...SIGNATURE 2 SERIES ...

Page 23: ...SIGNATURE 2 SERIES ...

Page 24: ...SIGNATURE 2 SERIES CSI WATER TREATMENT SYSTEMS 710 Orange St Ashland OH 44805 l PH 419 281 6829 l FAX 419 281 2375 www csiwater com ...