![CSI Fiberlink 5018A User Manual Download Page 8](http://html1.mh-extra.com/html/csi/fiberlink-5018a/fiberlink-5018a_user-manual_2692669008.webp)
Page 8
Fiberlink® 5018A User’s Manual
Fiberlink® 5018A
Signal and Power Connections
The 5018A is designed to operate in any available position in a model 6000A cardcage.
When installed, all operating power is provided by the card-cage.
The 5018A is ESD protected to + 10 kV on all inputs and outputs.
Data Connector Pin Out:
RS-232 Signal Connections:
Description
EIA Designation
Terminal Positions
Chassis Ground/Common
(AA)
1
Transmit Data
(BA) (input)
2
Receive Data
(BB) (output)
4
Signal Common
(AB)
1
All other terminal block positions should not be connected for this format.
RS-422 Signal Connections:
Chassis Ground
1
Transmit Data (+)
(input)
2
Transmit Data (-)
(input)
3
Receive Data (+)
(output)
4
Receive Data (-)
(output)
5
All other terminal block positions should not be connected for this format.