Fiberlink® 5018A User’s Manual
Fiberlink® 5018A
Installation instructions
There are no operating controls on the universal data transceiver. Simply set the mode of
operation with the internal DIP switches and then connect the signal, power supply and
fiber optic cables between the two units.
1.
Connect the data processing equipment to be used to the 6 position terminal block
on the 5018A .
Refer to the signal and power connections section on page 10 for specifics
.
Be certain that the various connections are made properly. Also be sure to only use
the positions called out for any particular protocol.
2.
Set the internal DIP switches for the protocol, speed and mode of operation
according to the instructions beginning on page 10.
Note: As provided from the
factory, the unit is set for RS-232, point-to-point.
3.
Plug the unit into any free position in a model 6000A card-cage.
4.
Connect the 5018A units together with two conductor fiber optic cable. Be certain
that the “Transmit” connector of one unit is connected to the “Receive” connector of
the other unit.
5.
The system should now be operational.
Installation
The transmitting element in the Fiberlink® 5018A transmitter
unit contains a solid state Laser Diode located in the optical
connector. This device emits invisible infrared electromagnetic
radiation which can be harmful to human eyes. The radiation
from this optical connector, if viewed at close range with no
fiber optic cable connected to the optical connector, may be
sufficient intensity to cause instantaneous damage to the
retina of the eye. Direct viewing of this radiation should be
avoided at all times!