![CSI Fiberlink 5018A User Manual Download Page 11](http://html1.mh-extra.com/html/csi/fiberlink-5018a/fiberlink-5018a_user-manual_2692669011.webp)
Page 11
Fiberlink® 5018A User’s Manual
Fiberlink® 5018A
Use the following protocol-specific settings to finish configuring the MODE DIP switch
on your universal data transceiver.
RS-232 Point-to-Point (Factory-Default Setting)
1
2
3
4
5
6
7
8
O P E N
1 through 6 Off
1
2
3
4
5
6
7
8
O P E N
See Page 10
Mode
T/R
RS-232 Drop-and-Repeat
1
2
3
4
5
6
7
8
O P E N
1 through 6 Off
1
2
3
4
5
6
7
8
O P E N
See Page 10
Mode
T/R
When using this mode of operation, any RS-232 driver not transmitting data must be in the low or - voltage
state as per EIA RS-232D.
RS-422 Point-to-Point
1
2
3
4
5
6
7
8
O P E N
Switch 6 ON
1
2
3
4
5
6
7
8
O P E N
See Page 10
Mode
T/R
DIP Switch Settings
120 Ohm Termination
Switch 7 ON: data input
Switch 8 ON: data output
Not Applicable
Not Applicable