Product Registration Information

DISCLAIMER: All information and statements contained herein are accurate to the best of the knowledge
of Cellular Specialties, Inc. (CSI), but Cellular Specialties makes no warranty with respect thereto, including
without limitation any results that may be obtained from the products described herein or the infringement
by such products of any proprietary rights of any persons. Use or application of such information or
statements is at the users sole risk, without any liability on the part of Cellular Specialties, Inc. Nothing
herein shall be construed as licence or recommendation for use, which infringes upon any proprietary
rights of any person. Product material and specifications are subject to change without notice. Cellular
Specialties’ standard terms of sale and the specific terms of any particular sale apply.

The general safety information in this guideline applies to both operating and service personnel.
Specific warnings and cautions will be found in other parts of this manual where they apply, but
may not appear in this summary. Failure to comply with these precautions or specific warnings
elsewhere in the manual violates safety standards of design, manufacture, and intended use of
equipment. Cellular Specialties, Inc. assumes no liability for the customer’s failure to comply with
these requirements:

Grounding

This Digital Repeater system is designed to operate from 100-240 VAC and should always
be operated with the ground wire properly connected. Do not remove or otherwise alter the
grounding lug on the power cord.

Explosive Atmospheres

To avoid explosion or fire, do not operate this product in the presence of flammable
gases or fumes.

Lightning Danger

Do not install or make adjustments to this unit during an electrical storm. Use of a suitable

lightning arrester, such as CSI’s model number CSI-CAP, is very strongly recommended.

No User Serviceable Parts Inside

HAZARDOUS VOLTAGES ARE PRESENT WHEN THE COVER IS REMOVED.

 Opening the

chassis will void your warranty. If you suspect a malfunction with this product, call your dealer or
the Cellular Specialties Support Line at: 

(603) 626-6677, Toll Free (USA) 1-877-844-4274

.

Safety Guidelines

This guide should be applied whenever a need exists to add Digital Repeater capability to an
existing system or when this capability is being included with a new installation.

Application

Document Purpose / Intended Users

The purpose of this document is to provide a step-by-step procedure to help the experienced
technician/engineer install and commission an in-building wireless enhancement repeater
system using CSI’s Digital Repeater. Following the procedures outlined will minimize risks
associated with modifying a live system and prevent service interruptions. This document
assumes the technician/engineer understands the basic principles and functionality involved
with Repeater and in-building systems. It is geared to the practical concerns of the installer.

The serial number may be found on the label on the bottom panel near the power
connectors. Note this number below. Retain this manual, along with proof of pur-
chase, to serve as a permanent record of your purchase.

MODEL NUMBER

SERIAL NUMBER

DATE OF PURCHASE

POINT OF SALE COMPANY

Summary of Contents for CSI-DSP85-PS7

Page 1: ...CSI DSP85 PS7 CSI DSP85N PS7 CSI DSP85 PSS8 CSI DSP85N PSS8 Installation Manual...

Page 2: ......

Page 3: ...Model 13 Dry Contact Terminal 14 Optional Accessories 14 Circuit Operational Description 15 Important Installation Notes 15 Functional Block Diagram 15 Mechanical Specifications Weather Resistent Mode...

Page 4: ...r otherwise alter the grounding lug on the power cord Explosive Atmospheres To avoid explosion or fire do not operate this product in the presence of flammable gases or fumes Lightning Danger Do not i...

Page 5: ...filter set configurations stored in memory determine the unit s adaptability to various field applications The following pages describe the public safety band plan as well as the convention CSI uses...

Page 6: ...MHz 2nd Channel Block Downlink Stop Freq of 773 0000 MHz with standard guard band Band ID Start Channel 1st Block see formula End Channel 1st Block see formula Underscore Indicates the Gap Between Ch...

Page 7: ...k Start Freq of 866 1000 MHz 2nd Channel Block Downlink Stop Freq of 867 0125 MHz with standard guard band Band ID Modulation ID Start Channel 1st Block see formula End Channel 1st Block see formula U...

Page 8: ...condition such as insufficient antenna isolation and will need to be addressed by either the system software or a technician to be reset to original system settings using the GUI or menu driven user i...

Page 9: ...ph Display ILLUMINATED BARS SIGNAL AT INPUT CONNECTOR 0 1 2 3 10 81 dBm 81dBm to 79dBm 78dBm to 75dBm Adjacent Channel Interference 4 5 6 7 8 9 74dBm to 71dBm 70dBm to 67dBm 66dBm to 63dBm 62dBm to 59...

Page 10: ...o reject these unwanted signals In some instances the donor antenna can be reoriented horizontally to place the interference source in an antenna pattern null There also may be some cases where the in...

Page 11: ...Attenuator Selection Guidelines Accurate attenuator values need to be chosen to ensure that the maximum total power higher of Composite or In Band Input applied to the donor and server port s does no...

Page 12: ...PLATE OPTIONAL 5 1EA 750 2172 002 P S MOUNTING BRACKET X WILL VARY WITH MODEL AND BAND ORDERED The following diagram illustrates the best method for mounting the repeater to a wall in an typical inst...

Page 13: ...ation Note for optimal cooling the unit should be mounted vertically on a wall with the antenna ports down ITEM QTY PART DESCRIPTION 1 1EA CS10 XXX 4XX DSP85N REPEATER 2 1EA 750 2268 001 MOUNTING PLAT...

Page 14: ...698 2 2K 7 10 UPS Battery backup 2 hr Single band 1 hour dual band model number CS48 985 600 Battery backup 4 hr Single band 2 hour dual band model number CS48 985 601 Power Dividers 2 1 model number...

Page 15: ...then processes the resultant digitized IF signal that was previously generated by an Analog to Digital Converter The processed filtered digital signal is fed to a Digital to Analog converter and then...

Page 16: ...Height 4 69 in Width 18 62 in Depth 11 25 in Heat Output 500 BTU Hr Color Satin Black Box Weight 35 5 16 103 lbs kg Box Thermal Management Convection cooled Large heatsink Surface Coating Powder Coat...

Page 17: ...dB steps RMS Vector Error EVM 3 max TDMA EDGE W CDMA CDMA2000 P25 CDMA RHO 0 98 min CDMA2000 1x EVD0 Spurious Emissions Applicable Documents FCC 13 dBm max Per FCC part 2 and 90 Industry Canada 13 dB...

Page 18: ...18 CC NC NO ETHERNET USB COM 1 COM 2 POWER DL PWR ALARM UL PWR TO OUTSIDE ANTENNA TOINSIDE ANTENNA Mechanical Drawing Standard Model...

Page 19: ...19 Mechanical Drawing Weather Resistent Model TOINSIDE ANTENNA TOOUTSIDE ANTENNA USB ETHERNET POWER CC NC NO...

Page 20: ...hat has a static IP Select Use the following IP Address and enter the IP Address as follows 192 168 1 x where x any number from 2 to 254 inclusive other than 100 The subnet mask is 255 255 255 0 Quest...

Page 21: ...software version 2 2 4 or prior only letters numbers and underscores are acceptable nomenclature In units with software version 2 3 0 and up Underscores are not acceptable however hyphens are accepta...

Page 22: ...the Program a Filter page below The user may select the desired filter by pressing the band sub band and modulation selection buttons Undesired bands sub bands if lit will require the user to manually...

Page 23: ...ofessional for proper setting requirements If the repeater includes a modem kit click on Remote Network in the navigation box and the screen below is displayed Highlight the carrier on whose network t...

Page 24: ...Contact CSI for updates and instructions System Health Install Upload The user may clear LED indicators alarms and the Event Log by clicking the Clear Log button If required in your municipality visi...

Page 25: ...are the only acceptable nomenclature for the Location field and hyphens may not be used as the first or last character Email Configuration page allows the user to enter up to five Email addresses to w...

Page 26: ...ss to the repeater TMI also known as the console interface is made by connecting a serial cable optional as shown in figure 1 from the serial connector of the laptop to either of the serial ports on t...

Page 27: ...e latest TeraTerm Pro Web release Version 3 1 3 October 8 2002 ttpro313 zip When the program is started the following screen is displayed Select the Serial radio button and press OK as shown below Not...

Page 28: ...og screen Go to the setup dropdown menu and select Serial port to make changes to the serial port setup Configure the terminal program for the correct COM port in this case COM 1 and 115200 baud rate...

Page 29: ...r entering the password and pressing return the TMI main menu will appear Note by default the Set Parameters option is disabled To re enable the user will press 1 and will be prompted for a username a...

Page 30: ...by typing the desired gain at the prompt The user is then returned to the previous menu Each Set Parameter selection when chosen will be expanded to allow changing or setting of that parameter For exa...

Page 31: ...he IP addresses of both the computer used and the repeater must use the same group of IP address number sets For example the repeater ships with the default IP address of 192 168 1 100 and a Sub Net M...

Page 32: ...h will require the user to log in The default user name is user The default password is csi1234 In the field after the prompt type the user name and password After typing the password press the enter...

Page 33: ...become fully functional contact the service provider In addition an IP address must be obtained and entered into the CSI DSP85 PSS8 Once the modem has been installed and activated it can be accessed...

Page 34: ...on your Windows computer Click in the Network Connections Icon in the Control Panel See below Right click on Local Area Connection and select Properties Scroll down to Internet Protocol TCP IP and cli...

Page 35: ...ered Click OK then OK again and retry connection A crossover Ethernet cable supplied must be used for Web Interface access As a reminder you must verify the Ethernet port on your laptop is powered If...

Page 36: ...about one tenth of RBW Other settings like span are whatever is appropriate One should also make sure that there are no signals above the top of the screen If you cannot see an adjacent out of band si...

Page 37: ...r ranty shall be applicable with respect to any product which Seller replaces pursuant to it SELLER MAKES NO WAR RANTY EXPRESS OR IMPLIED OTHER THAN AS SPECIFI CALLY STATED ABOVE EXPRESSLY EXCLUDED AR...

Page 38: ...Indicators 7 Lightning Danger 4 Linear Gain 16 Liner Output Power 16 Local Network 20 login 19 M Manual Gain Control 16 Maximum RF input Power 16 Modem Interface 32 modulation selection 21 Monitoring...

Page 39: ...39 Notes...

Page 40: ...960 1041 005 rev B ECO 2241...