background image

3. LI MODE

 

AC Power is connected with the wall 
socket properly, Press "MODE" key, The 
LCD signal will show "LI", the charger is 
switched to LiFePO4 battery mode 
(LiFePO4), correctly connect the charger 
output leads (Red"+", Black"-") to battery 
positive and negative 

4. DC ADAPTER MODE: 

A.C Power is connected with the wall 
socket properly, Press "MODE" key and 
hold for 3-5 seconds, The LCD signal will 
show "DC", the charger is switched to DC 
Adapter with 12V 6Amp (MAX output 72 
Watt) 

5. LOW TEMPERATURE CHARGING 
MODE

 

When the ambient temperature is below -
10 degrees, Press "MODE" Key, The LCD 
signal will show

 this mode can be set 

 

"     "

for battery charging to facilitate the rapid 
recovery of the battery capacity. 

NOTED: ONLY FOR 12V LEAD ACID 
BATTERIES (Standard, AGM) 

6. BATTERY TESTER MODE

 

The charger can be used for testing your 
battery healthy. Correctly connect your 
battery positive and negative with the 
charger leads, no need to connect AC 
power. 
The LCD display will indicate battery 
indicator 20-100%, "BAT LOW" will be 
indicated while the battery voltage is LOW, 
easily to know your battery status. 

Summary of Contents for CS1210L

Page 1: ......

Page 2: ...ord when disconnecting the charger 8 Make sure cord is located so that it cannot be stepped on tripped over or otherwise subjected to damage or stress 9 Study all the battery manufacturers speci c pre...

Page 3: ...not over ll For a sealed battery or a battery without cell caps carefully follow manufacturers recharging instructions e Study all battery manufacturers speci cations such as removal of cell caps duri...

Page 4: ...o the charger The charger output depends on the condition of the battery it is charging When the battery is fully charged the Good will indicate and battery indicator will show 100 then the charger wi...

Page 5: ...ry indicator light will ash which means charging has not been initiated to initiate charge on a battery that is below 2 0 volts you must fool the battery charger circuitry by momentarily jumping the d...

Page 6: ...ed to standard battery mode GEL VRLA SLA correctly connect the charger output leads Red Black to battery positive and negative 2 AGM MODE AC Power is connected with the wall socket properly Press MODE...

Page 7: ...2V 6Amp MAX output 72 Watt 5 LOW TEMPERATURE CHARGING MODE When the ambient temperature is below 10 degrees Press MODE Key The LCD signal will show this mode can be set for battery charging to facilit...

Page 8: ...LCD Signal INDICATION 1 Pd lead acid battery charging mode...

Page 9: ...with the wall socket properly Press MODE Key for 3 5 seconds The device will enter DC adapter mode The LCD signal will show DC It can supply 120 Watt output 12V DC 10 Amp 3 Battery tester Mode The cha...

Page 10: ...battery is worn out or is possibly defective Suggest replacing with a new battery The charger is charging but the 20 100 signal does not come on A The battery is worn out or is possibly defective Sugg...

Page 11: ...y constant current taking the battery up to 80 of its full capacity 4 Adaptive Phase The charger can make a calculated guess for the battery capacity Automatically adjust the charging current to avoid...

Page 12: ...battery to recover prior to bulk charge 2 Bulk Charge Phase With the battery now having been activated and gone through the Soft Start phase as needed the bulk charge phase gives the battery constant...

Page 13: ...Protection Yes Short Circuit Protection Yes Spark Proof Yes Cooling Natural Operating temperature 10 50 C Fuse Protected Cables 10A Waterproof IP64 Battery Capacity Charging and maintenance all 30 300...

Reviews: