background image

cod.61

181

10EN04-2015

Via Padania, 35 - 31020 San Vendemiano (TV) - ITALIA
E.mail: [email protected] - Website: www.csthermos.it

INSTRUCTION MANUAL

INGLESE

BIOHYDRA

BIOHYDRA MAXI

BIOHYDRA MAXI 28

BIOHYDRA COMFORT

TESI H2O

Summary of Contents for BIOHYDRA

Page 1: ...INSTRUCTION MANUAL INGLESE BIOHYDRA BIOHYDRA MAXI BIOHYDRA MAXI 28 BIOHYDRA COMFORT TESI H2O...

Page 2: ...the end of its working life the product must not be disposed of with household waste but be taken to a special differentiated waste collection center or to a dealer providing this service To dispose o...

Page 3: ...t smells during functioning may be caused by the type of pellets used Possible noises during functioning are normal caused by the settlement of assembled parts Store bags of fuel at least 1 metre away...

Page 4: ...orrosive gas reducing machine performance release polluting substances into the atmosphere and window incrustation Regulations on this matter have established that products using this type of fuel mus...

Page 5: ...tem return 3 4 5 Boiler return 3 4 6 Circulator 7 Safety valve discharge 3Bar 8 Boiler discharge cock 9 Expansion tank 10 System flow 3 4 11 Hot water outlet 3 4 Comfort model 12 Cold water inlet 3 4...

Page 6: ...ENGLISH 5 EXTERNAL DIMENSIONS BIOHYDRA Model BIOHYDRA MAXI Model 1245 590 630 scarico fumi output tube sortie fum es 900 640 1325 420 scarico fumi output tube sortie fum es...

Page 7: ...H 6 BIOHYDRA COMFORT Model POSTERIOR VIEW OF BIOHYDRA COMFORT 900 640 1 325 5 50 250 250 11 5 23 0 sc arico fumi output tube sortie fum es D 80mm 140mm 80mm 200mm 120mm 180mm 270mm 650mm 800mm 1080mm...

Page 8: ...GLISH 7 BIOHYDRA MAXI 28 Model POSTERIOR VIEW OF BIOHYDRA MAXI 28 900 640 1325 550 210 210 100 260 scarico fumi output tube sortie fum es D 100mm 140mm 200mm 270mm 650mm 800m m 1080mm 1065m m 10 4 5 7...

Page 9: ...irculator 7 Safety valve discharge 3Bar 8 Boiler discharge cock 9 Expansion tank 10 System flow 3 4 EXTERNAL DIMENSIONS TESI H2O Model 1285mm 960mm 350mm scarico fumi flueheader sortie fum es scarico...

Page 10: ...T TAN K C APACITY K g 26 70 70 70 26 HEATED VOLUME m3 300 380 300 380 400 500 300 380 220 300 S MOKE OUTLET DIAMETER mm 80 80 100 80 80 MAXIMU M S MOKE TEMPE RATURE C 160 160 160 160 160 ELECTR ICAL P...

Page 11: ...SYSTEM AND THE BOILER AT EVERY FILLING CONNECT THE SAFETY VALVE DRAIN AND BRING IT OUTSIDE THE BOILER A DIRT SEPARATOR WITH MAGNET MUST BE INSTALLED ON THE RETURN CIRCUIT TO PROTECT THE BOILER S INTE...

Page 12: ...mestic hot water production layout CIRCUITO RISCALDAMENTO COLLETTORE USCITA ACQUA CALDA SANITARIA ENTRATA ACQUEDOTTO CARICO IMPIANTO CIRCOLATORE HEATING SYSTEM HOT WATER OUTLET COLD WATER INLET DOMEST...

Page 13: ...TARY WATER TANK SHOULD IT BE WORN OUT REPLACE IT IMMEDIATELY TO PREVENT FAILURES DUE TO CORROSION CIRCUITO RISCALDAMENTO COLLETTORE CIRCOLATORE CARICO IMPIANTO USCITA ACQUA CALDA SANITARIA ENTRATA ACQ...

Page 14: ...nal contact must be covered with tiles or at least well insulated The stack must be wind resistant with an internal section that is equal to that of the chimney a useful section at least twice the siz...

Page 15: ...y connect it to the boiler using a T pipe connection using a 80 100 pipe fitting see fig 8 FLUE DIAM ETER OPINION Tube length less than 5 m 80 mm Correct Tube length more than 5 m 100 mm Mandatory For...

Page 16: ...s plants wood or elements that could be visually damaged walls windows within 3m of the flue WARNING Seeing that regulations regarding installation of pellet fuelled boilers are constantly being updat...

Page 17: ...plaque electric power nominal voltage etc that the plant has a sufficient earth connection according to nominal regulations in vigour earth connection is obligatory by law the power cable should never...

Page 18: ...ENCODER CLOCK BATTERY BOILER CIRCULATOR DIVERTER VALVE IGNITION RESISTOR CRUCIBLE MOTOR COMBUSTION FAN DISPLAY LOAD AUGER MOTOR MIXING AUGER MOTOR BOILER PRESSURE SWITCH AIR PRESSURE SWITCH BOILER SAF...

Page 19: ...or combustible walls keep a safe distance of 30cm from the rear and sides of the machine Avoid leaving any type of flammable or combustible materials within 1m of the heat waves from the glass window...

Page 20: ...ols phase with fire pot cleaning before loading fuel Charged Start up phase with fuel load in the burner while supplying power to the resistors at the same time Pause Pause while awaiting flame St fir...

Page 21: ...ate an homogenous mixture The menu LOAD allows to vary the quantity of combustible to be loaded and it is subdivided into 3 levels of increa se and 3 levels of decrease each level consists of 0 2 se c...

Page 22: ...r yes ON00 00 OFF00 00 ON00 00 OFF00 00 ON00 00 OFF00 00 ON00 00 OFF00 00 ON00 00 OFF00 00 Press to modify Press to modify Press to modify Press to modify Press to modify Press to modify Press to modi...

Page 23: ...afety thermostat clean the inside of the stove reset the thermostat and restart the stove Thermostat auger Intervention on the part of the fuel auger safety thermostat clean the inside of the stove re...

Page 24: ...r fig B using the flexible pipe supplied fig E to connect to your vacuum cleaner To remove any encrustation scrape the inside of the wheel holes fig C with the tip of the supplied accessory fig F remo...

Page 25: ...er from under the burner Empty out all the ash taking care that there are no hot ashes fig A Carefully remove all ash from the bottom to avoid malfunctionings fig B Place the ash drawer back in its se...

Page 26: ...l all ash has fallen into the below collecting drawer Now remove the burst protecting plate by loosening the relative wingnuts B and suck all fuel residue present inside the fumes conduit C using the...

Page 27: ...ertical fumes conduit and the entire flue must be checked and cleaned at least once a year We recommend the use of a specialised technician for a thorough and professional cleaning COM BUSTION AIR INT...