ENGLISH
19
12. CONTROL PANEL DISPLAY
D ESC RIPTION OF DISPLA Y B UTT ONS
Ke y -
turns the boiler on and off in manual mode (keep pressed for 2 sec.), eliminates alarms and exits
programming.
Ke y SET -
changes the screen and confirms set data
Ke y -
key for increasing values being set
Ke y -
key for decreasing values being set
MEANI NG OF L ED LIGHTS
SUMMER
The "permanently" on LE D indicates the hot domestic water boiler is satisfied.
The "flashing" LE D indicates the boiler is heating the hot domestic water boiler.
WINTE R
The "permanently" on LE D indicates the heating system is not requesting heat.
The "flashing" LE D indicates the heat request from the heating system.
13. OPERATIONAL PHASES
DISPLA Y
MEANI NG
Clean.
Pre-ventilation and safety controls phase, with fire pot cleaning before loading fuel.
Charged
Start-up phas e with fuel load in the burner while supplying power to the resistors at the
same time.
Pause
Pause while awaiting flame.
St. fire
Waiting phas e during which the start-up must take place.
Stabil.
Stabilisation phase, after the flame has started, wit h a medium size load of fuel.
fire
Burner operational adjustment phase where power can varies from 1 to 6
Turn off
Timed turn off phase associated to an interruption in the fuel for fire pot cleaning and
waiting for the flame to be totally extinguished.
Off
Turned off status until there is an following request for heat
Stand by
Switch-off for reached heating and domestic hot water temperat ure
IN CAS E OF AN ALA RM, W AIT FO R TH E EN D OF T HE T U RNI NG OFF PH AS E
SET
Set day and time
During operation
Recorded boile r te mperature
Recorded domestic water
Operational powe r
Lun 09:00 Tc 65°
Accesa 5 Ts 55°
OFF