background image

 

 

13.8VDC 1 Amp Regulated

Power Supply

+

-

To select between Wiegand and Clock + Data Output

LK1 ON- Wiegand
LK1 OFF – Clock + Data

Door 1 reader

Black (GND) 

GND

White ( DATA)

IN1

Blue (Green LED)  LED1
Red (+5V)

+V

R

e

ad

e

r C

a

b

ling:

U

s

C

A

T

5

 c

abl

e

. M

a

xi

m

um

 5

0

 m

e

te

rs

.

If

 y

o

u r

ev

er

s

e t

h

re

la

co

nt

a

ct

 (

m

ak

e t

h

re

la

no

rm

al

ly

 open

),

co

n

n

ec

t t

h

YEL

L

O

W

ca

bl

e (

R

ed

 LE

D

) t

o

 t

he c

o

nt

ro

lle

r LE

D

 p

in 

in

s

tead

 o

f t

he b

lue

 c

ab

le.

Wiegand

Clock + Data

DATA1

DATA

DATA 0

CLOCK

LED

LED

GROUND

GROUND

LK6

READER 1

0

V

 NO

C2

 N

C

2

  

  0

V

  NO

1 C1

 NC1

+

1

2V

  0
V

     F

T

 F

T

G

N

D

 

I/

O

0V  

IN1 

LED1

+V      0V 

IN2

LED2

+V       0V  

IN3 IN4

+5V

1

READER 2

IN1
IN2

IN3
IN4

+

-

2

EXIT REQ

LK1

Fire  Trip.  Link  must  alway s be on 

unless  wired  into a fire trip

 

Summary of Contents for ACE-CONVERTER

Page 1: ...so manufactures a version of the key which is programmed with a site code and card number and which transmits a 26 bit Wiegand format string this may be more suitable for for applications where a site code is required Features Dedicated single purpose controller no programming necessary Easy installation On board link selects either wiegand or clock and data output Operates from 12VDC or 5VDC supp...

Page 2: ...d format output IN3 DATA0 and IN4 DATA1 Configuring the converter The converter has a small link labelled LK5 This link should be OFF to transmit in Clock and Data format or ON to transmit in Wiegand format Configuring a CS Controller If using the converter with a CS controller the firmware in the controller should be either Magstripe or Wiegand firmware With magstripe firmware set the card option...

Page 3: ...t 2 LK19 LK18 ON Reader on Port 3 or 4 LK17 LK8 ON SOFTWARE Set the controller type as CARD Set the reader type as WIEGAND Clock Data Format CONTROLLER Set appropriate controller links LK19 LK18 LK17 LK8 LK20 OFF LK21 DOWN LK22 UP V 5 volts Reader on Port 1 no link changes Reader on Port 2 LK19 ON Reader on Port 3 or 4 LK17 ON SOFTWARE Set the controller type as KEY Set the reader type as CLOCK DA...

Page 4: ...ters If you rev ers e t he relay cont act make t he relay normally open connec t the YELLOW cabl e Red LED to t he c ont roller LED pin instead of the blue c able Wiegand Clock Data DATA1 DATA DATA 0 CLOCK LED LED GROUND GROUND LK6 READER 1 0V NO2 C2 NC2 0V NO1 C1 NC1 12V 0V FT FT GND I O 0V IN1 LED1 V 0V IN2 LED2 V 0V IN3 IN4 5V 1 READER 2 IN1 IN2 IN3 IN4 2 EXIT REQ LK1 Fire Trip Link must always...