www.cs-lab.eu
CS-Lab s.c. | CSMIO-MPG manual pulse generator module
8
The outputs have 50mA load. Do not
overload outputs. You should also pay
attention, if large inductances are
connected, you may need to use an
additional surge diode, preferably as
close to the coil as possible.
4.2
DB25 Connector.
4.3
Connector for CSMIO/IP (or previous module connection)
PIN number
Description
1
24VDC output (250mA)
2
Digital output 0
3
5VDC output (250mA)
4
A- (TTL 5V) input
5
B- (TTL 5V) input
6
Analog input 1 (0-5V)
7
Digital input 0 (x1)
8
Digital input 2 (x100)
9
Digital input 4 (Y axis)
10
Digital input 6 (A axis)
11
Digital input 8 (C axis)
12
Shared power supply (-)
for 0÷9 inputs
13
E-Stop 2
14
GND
15
Digital output 1
16
A+ (TTL 5V) input
17
B+ (TTL 5V) input
18
Analog input 0 (0-5V)
19
GND
20
Digital input 1 (x10)
21
Digital input 3 (X axis)
22
Digital input 5 (Z axis)
23
Digital input 7 (B axis)
24
Digital input 9
25
E-Stop 1
PIN
Description
1
CAN H
2
-
3
-
4
-
5
GND
6
CAN L
7
RS485 B-
8
RS485 A+
9
-
For proper module operation CAN H, CAN L, and GND must be connected to the CSMIO module.
Connections RS485 B- and are used in other CSMIO modules and their connection may
be required for proper operation.
Max. allowed load of 250mA/pin of
the 5V and 24V connector power.