2.2 Connection of third party sensors
DS 52 has one analogue sensor input for connection of sensors with 0/4…20
mA signal.The sensor input is configurated on our premises (according to the
customers specification in the order).
Sensors with 0
/4…20 mA-current signal are connected as follows:
V+ max:
24 VDC
100 mA
* A bridge circuit is inserted ex factory . For signal transfer please remove the
bridge circuit and attach the connection cables. Attention: Current loop has
to be closed!