5.  Calibration/adjustment

 

 

At CS Instruments

 

According to DIN ISO certification of the measuring instruments we 
recommend to calibrate and if applicable to adjust the instruments regularly at 
the manufacturer. The calibration intervals should comply with your internal 
specificaton. According to DIN ISO we recommend a calibration interval of one 
year for the instrument DS 52 including probes. 

 
6.  Warranty 

 
If you have reason for complaint we will of course repair any faults free of 
charge if it can be proven that they are manufacturing faults. The fault should 
be reported immediately after it has been found and within the warranty time 
guaranteed by us. Excluded from this warranty is damage caused by improper 
use and non adherence to the instruction manual. 
 
The warranty is also cancelled once the instrument has been opened - as far 
as this has not been mentioned in the instruction manual for maintenance 
purposes - or if the serial number in the instrument has been changed, 
damaged or removed.   
 
The warranty time for DS 52 is 12 months, the warranty time of the accessories 
is 6 months. Warranty services do not extend the warranty time. 
 
If in addition to the warranty service necessary repairs, adjustments or similar 
are carried out the warranty services are free of charge but there is a charge 
for other services such as transport and packaging costs. Other claims, 
especially those for damage occurring outside the instrument, are not included 
unless responsibility is legally binding. 
 

After sales service after the warranty time has elapsed

 

We are of course there for you even after the warranty time has elapsed. In 
case of malfunctions please send us the instrument with a short-form 
description of the fault. Please do not forget to indicate your telephone number 
so that we can call you in case of any questions. 
 
 

Summary of Contents for 0500 0008

Page 1: ...V1_03_2016 1 Instruction Manual Digital Display DS 52 in wall housing Order no 0500 0008 for 0 4 20 mA sensors...

Page 2: ...gh standard products every year There are a few good reasons for doing so The cost performance ratio reliable quality at a fair price We have the ideal solutions for your measuring tasks based on our...

Page 3: ...the delivery capability or use of this device Initiation electrical connection When operating electrical instruments it is unavoidable that certain components are energised dangerously Work at electr...

Page 4: ...of CS Instruments sensors AC Power 230 VAC 50 Hz Attention Mains voltage NC und COM are closed in case of alarm exceeding voltage drop sensor break A bridge circuit is inserted ex factory For signal...

Page 5: ...ensor Terminal connector M12 7 8 9 101112131415 1 2 3 4 5 6 Sensor 230 VAC A1 2 A1 1 PE N L V GND I I I SIG 1 2 3 4 5 FA 515 Braun brown Blau blue CS Sensor Terminal connector M12 A bridge circuit is...

Page 6: ...or input is configurated on our premises according to the customers specification in the order Sensors with 0 4 20 mA current signal are connected as follows V max 24 VDC 100 mA A bridge circuit is in...

Page 7: ...9 101112131415 1 2 3 4 5 6 Sensor 230 VAC A1 2 A1 1 PE N L V GND I I I SIG 0 1 2 5 4 3 Netzanschlussleitung Supply cable gr n gelb green yellow blau blue braun brown grau grey schwarz black Lampe lamp...

Page 8: ...2 nOr alters press shortly HY 2 2 0 alters press shortly rEv rEv With alarm threshold 1 scaling up with scaling down nOr Normal means Alarm 1 in case of threshold exceeding rEv Reverse means Alarm 1...

Page 9: ...with and whether you want to connect a sensor with 0 20 mA signal or with 4 20 mA signal 4 mA 0 20 mA 500 With and you can set the lower scaling value 4 mA resp 0 mA of your sensor With and you set th...

Page 10: ...instrument has been opened as far as this has not been mentioned in the instruction manual for maintenance purposes or if the serial number in the instrument has been changed damaged or removed The wa...

Page 11: ...or sensors with 0 20 mA or 0 4 20 mA signal Connectable in 2 3 or 4 wire technologie possible with 24 VDC supply Burden analogue input 100 Ohm Accuracy analogue input max 20 A typical 10 A Sensor supp...

Page 12: ...ogue sensor input for sensors with 4 20 mA or 0 20 mA signals 2 alarm relays change over contact 250 VAC max 3 A alarm values freely adjustable 0500 0008 Options Option for DS 52 LED display Supply 24...

Page 13: ...V1_03_2016 13 Notes...

Page 14: ...55 Harrislee Phone 49 0 461 700 2025 Fax 49 0 461 700 2026 E Mail info cs instruments com www cs instruments com Sales office South Germany CS Instruments GmbH Zindelsteiner Stra e 15 78052 VS Tannhei...

Reviews: