23
Parameters table
N°
Description
Adjustment range
Factory setting
Remarks
01*
Adjustment of temperature
difference
before restart
1~18°C
1°C
Adjustable
02
Reserved - Do not adjust
Reserved
03
Reserved - Do not adjust
Reserved
04
Adjusting the cooling temperature
8~28°C
27°C
Adjustable
05
Adjusting the heating temperature
15~40°C
27°C
Adjustable
06
Reserved - Do not adjust
Reserved
07
Reserved - Do not adjust
Reserved
08
Reserved - Do not adjust
Reserved
09
Setting the compensation coefficient of the temperature water inlet
-5~15°C
0°C
Adjustable
10
Reserved - Do not adjust
Reserved
11
Auto-activation time before deicing commences
20~90 min
45 min
Adjustable
12
Deicing activation temperature
-15~1°C
-3°C
Adjustable
13
Maximum deicing duration
5~20 min
8 min
Adjustable
14
Deicing deactivation temperature
1~40°C
20°C
Adjustable
15
Reserved - Do not adjust
Reserved
16
Reserved - Do not adjust
Reserved
17
Expansive valve action period
20~90s
30s
Adjustable
18
Reserved - Do not adjust
Reserved
19
Reserved - Do not adjust
Reserved
20
Reserved - Do not adjust
Reserved
21
The mini opening for the electrical expansive valve
50~150
80
Adjustable
22
Reserved - Do not adjust
Reserved
23
Reserved - Do not adjust
Reserved
24
Reserved - Do not adjust
Reserved
25
Reserved - Do not adjust
Reserved
26
Reserved - Do not adjust
Reserved
27
Reserved - Do not adjust
Reserved
28
Filtration pump servo-control mode
0 ~ 1
0
Adjustable
29
Max water outlet temp set in heating mode
25~40°C
40
Adjustable
*
Parameter 01 allows you to change the
deviation
degree interval from the requested temperature so that the heat pump starts again.
Example : If the value of parameter 01 is 3°C, after reaching the required temperature (eg 27°C), the heat pump will restart when the pool
temperature drops to 24°C (27 - 3).