Menu
Comment
Video missing
Press ENTER to access menu. Rotate ADJUST to enable or disable
reporting. Press ENTER to action command.
Ds
disable,
En
enable
Menu
Comment
Embedder C
silence detect
Each output channel can be monitored independently.
Rotate SCROLL to find the channel silence alarm to be configured.
Press ENTER to access the selected channel. Rotate ADJUST to flag
or mask reporting.
Press ENTER to action command.
Msk
disable,
Fl
G
enable
Embedder D
silence detect
Rotate SCROLL to find the channel silence alarm to be configured.
Press ENTER to access the selected channel. Rotate ADJUST to flag
or mask reporting.
Press ENTER to action command.
Msk
disable,
Fl
G
enable
Silence Delay
The delay before a silence alarm is reported can be varied from
1-120 seconds. Note this is a global control and will similarly affect
all flagged channel silence alarms.
Miscellaneous menu (Factory Reset)
At present, the only control available in the miscellaneous menu is the Factory Reset. This
control can be used to return the TANDEM HD-20 to its default condition. Note the
default conditions will be dependent on any sub-PCBs fitted.
Menu
Comment
Factory Reset
Press ENTER to access factory-reset menu.
SCROLL to select yes (Y).
Press ENTER to assert.