Control Descriptions
GPI Trigger
Select either level or pulse to trigger GPI
recall.
GPI Level
Select either active low or high level to
trigger the GPI recall.
Resets
Reset ViViD 3G settings to default values.
Fact Res Exc
Presets
Reset the board to default settings but leave preset memories
unaffected.
Fact Res Inc
Presets
Reset the board to default settings and erase preset memories.
GPO Alarms
The GPO 5 and GPO 6 outputs are reserved for alarm indication and may each be
assigned to any of the three video alarm conditions (four conditions on 3GS and 3GS-
20). Black and Frozen alarms have a delay timer to set the amount of time that the alarm
condition must exist before the GPO is asserted.
GPO 5/6 Asserted
On if the alarm conditions are met.