Crystal Vision
Control and Status monitoring
Reading card edge LEDs
Card edge LEDs may be used in conjunction with status information from any connected
remote status panel display or from VisionWeb if available.
Refer also to the troubleshooting chapter for more help with solving problems and monitoring
status information.
The following table summarises the card edge LED functions and colours:
LED Name
#
LED
Colour
Function when ON
Function when Off
1
PSU
Green
Good power supply (PSU) rails
One or more of the monitor
supplies is out of specification
2
Lock
Green
3
HD
Yellow
Video input A standard is HD
(High Definition)
Input not present
4
SD
Yellow
Video input A standard is SD
(Standard Definition)
5
HD
Yellow
Video input B standard is HD
(High Definition)
Input not present
6
SD
Yellow
Video input B standard is SD
(Standard Definition)
7
G1
Yellow
Audio Group 1 present Ch. A
Audio Group 1 not present
8
G2
Yellow
Audio Group 2 present Ch. A
Audio Group 2 not present
9
G1
Yellow
Audio Group 1 present Ch. B
Audio Group 1 not present
10
G2
Yellow
Audio Group 2 present Ch. B
Audio Group 2 not present
Navigating card edge menus
To access the card edge menu system proceed as follows:
•
Press the up-arrow [
] until a top menu category is reached
•
Rotate the SCROLL/ADJ control until the desired menu category is found
•
Press ENTER to enter the sub-menus of that category
•
Rotate SCROLL/ADJ to select a sub-menu
•
Press ENTER to select the desired function. Selection will be indicated by the text
being displayed in
italic
text
•
Rotate ADJUST to make the desired change to the selected parameter. The display
changes to
italics
to indicate that a change has been made and requires confirmation
•
When required push ENTER to action the change. The display will return to normal
non-italic text.
•
Use the up-arrow [
] and SCROLL/ADJ control to navigate to further menus
TANDEM 320 User Manual R1.3
19