background image

Crystal Vision

 

Installation

 

Crystal Vision 

 

Installation

 

 

2   Installation 

These servicing instructions are for use by qualified personnel only. To reduce risk  of electric 

shock, do not perform any servicing other than that contained in the  Operating Instructions 

unless you are qualified to do so. Refer all servicing to qualified service personnel. Refer also to the 

General Safely Summary below. 

 

 

General Safety Summary 

The following warnings are intended for user guidance and safety. 

Ground   

This product must be grounded through the grounding conductor of the 

power cord. 

 

Power cable   

Use only power cords that meet the required specification for this product. 

 

Fuses   

To avoid fire hazard use only fuses of the type and rating specified. 

 

Service   

These servicing instructions are for use by qualified personnel only. To 

reduce risk of  electric shock, do not perform any servicing other than that 

contained in this manual unless  you are qualified to do so. Refer all 

servicing to qualified service personnel. 
Apart from procedures described in this manual there are no user serviceable 

parts within  the frame. If the frame requires any other servicing it should 

be returned to the manufacturer  or dealer. 
On no account should the unit be powered whilst any covers are removed. 

 

Ventilation 

The unit must have adequate ventilation. Installation should be in standard 19" 

racks  with  cool air  circulation  available  at  the  front.  The  left  and right 

ventilation grilles must not be  obstructed. 

 

EMC   

To comply with EMC regulations the following guide lines 

should be observed:  Do not operate this unit for extended periods 

with the front panel open. 

Do not use the frame unless all the rear connector positions are filled, 

either with Crystal  Vision Rear Modules, or with Crystal Vision 

blanking plates. 
Do not operate the equipment with covers or panels removed. 

 

General   

To avoid electric shock do not operate this product in wet or damp 

conditions. 

To avoid injury or fire hazard do not operate this product in an 
explosive atmosphere.  Only use this rack in conjunction with Crystal 
Vision modules designed for that purpose.

 

Indigo PSU Manual R1.2 

24/05/2010 

4

 

 

Summary of Contents for Indigo PSU-160i

Page 1: ...go frames Includes PSU 160i and PS 80i Crystal Vision Ltd Lion Technology Park Station Road East Whittlesford Cambridge CB22 4WL England Tel 44 0 1223 497049 Fax 44 0 1223 497059 sales crystalvision t...

Page 2: ...11 Reading LED status and active display messages 11 Replacing the mains input fuses 12 Indigo 1 DP 14 3 1 Frequently asked questions 15 4 Specification 16 Revision1 Indigo PSU 160i and dual PS 55i in...

Page 3: ...80 Watts power supply for the Indigo 1 DP frame All of the Indigo PSU s have a built in processor which communicates with the front panel display processor referred to as a PIC such information as pow...

Page 4: ...Crystal Vision Introduction The Indigo 2 Crystal Vision frame with front control panel open The Indigo 4 Crystal Vision frame with front control panel open Indigo PSU Manual R1 2 24 05 2010 3...

Page 5: ...to qualified service personnel Apart from procedures described in this manual there are no user serviceable parts within the frame If the frame requires any other servicing it should be returned to th...

Page 6: ...ey should both be the same version i e 2 x 160i The PSU 160i is not compatible with similar PSUs used on FR2AV and FR1AV Frames Indigo 1 DP power supply module The Indigo 1 DP is fitted with a pair of...

Page 7: ...odules are mounted into the Indigo 1 DP frame by way of a retained mother board This mother board which remains in situ contains the CPU alarm relay and low voltage fusing for the frame bays It is als...

Page 8: ...from GREEN to OFF every 2 3 seconds to warn that the switch is set to one instead of two Warning These servicing instructions are for use by qualified personnel only To reduce risk of electric shock d...

Page 9: ...free the fan connector plugs the PSU fan will stop and the front panel PSU FAN LED will change from green to red Removing the PSU fan assembly Lower PSU 160i front view In addition to the PSU and fan...

Page 10: ...switch behind the control panel is set correctly for the number of PSUs installed to prevent redundant PSU warnings Refitting the fan assembly To replace the PSU fan assembly proceed as follows Offer...

Page 11: ...e 2 pin 23 Remote 2 pin 5 Indigo 2 Indigo 4 Fourth Power Supply Relay Connections Description Pin number relay common open on fault close on fault Remote 4 pin 14 Remote 4 pin 23 Remote 4 pin 5 Indigo...

Page 12: ...low Change the panel fan Indigo 4 may be upper or lower fan PSU Fan Yell Grn None Normal operation Red Psu fan speed low Change PSU fan Indigo 4 may be upper or lower fan PSU Yell Grn None Normal oper...

Page 13: ...more details The PSU 150i 48V line fuse is located internally to the PSU module Replacing this fuse will involve dismantling the module See replacing PSU 150i 48V fuse Note The red LED built into the...

Page 14: ...awer and reconnect the power cords Rear connectors showing IEC mains inputs and fuse tray with main and spare fuses If a fuse blows repeatedly this indicates a fault either in the associated power sup...

Page 15: ...the same type and rating 5A 250V time delay 3 1 Frequently asked questions Why is the display black and or no LEDs illuminated Check that at least one frame PSU is functioning Check that the frame is...

Page 16: ...tch at the rear of the front panel is set correctly for the number of power supplies installed Why does the LOWER PSU LED flash from green to off This will occur if two PSUs are fitted when the Two On...

Page 17: ...ion Indigo PSU General Dimensions 268mm x 105mm x 38mm Power requirements 85 to 264 volts 47 to 400Hz Operating conditions 0 to 40 degrees C non condensing Ventilation front to sides without air filte...

Reviews: