5- 8
1. Unplug cooler from power source (
fig.1-1).
2. Empty and remove water bottle (
fig.2-1) and drain cooler reservoir through the faucets until
empty
(fig.2-2).If cooler is a hot and cold, the hot tank must be drained from the drain plug located
on the back of unit on the lower right side (
fig.2-3). Also, shut hot tank switch off.
CAUTION
The water in the hot tank is very hot; after unplugging cooler, allow 2 hours for water to cool down
before removing the drain cap to drain the system!
3. Remove top lid of cooler by turning counter clockwise or to the left
(fig.3-1). For Crystal Guard
and Aquaflo models, remove the Crystal Guard pin stopper at rear of outer edge of guard or ring
(fig.3-2).
4. Turn cooler around so you are facing the back of the unit, and remove the top of the two piece
blue, or white, insulation by lifting it straight up through the cooler top opening
(fig.4-1). Bottom in-
sulation piece remains on cooler.
. Refrigeration Repair System (RRS) Removal Procedure
figure 2-1 figure 2-2 figure 2-3
figure 3-1 figure 3-2
figure 4-1
figure 1-1