5- 10
9. The RRS system is now ready to be slid out of the plastic cabinet.
10. Hold the condenser on the right hand side and slowly lift and pull to free the RRS system from
the cooler body. Slowly work the unit from top to bottom until it starts to slide out. Once it starts
to come out, be careful of the small capillary tube (copper coil) located on the left side of the
compressor as it is very fragile
(fig.10-1), guide it by the cooler body with your hand. Then slide
the unit as far as possible to the left and the support stick on the right side will come by the body
(fig.10-2). Continue until the RRS is outside the cooler body and free standing on its own (fig.10-3).
figure 10-1 figure 10-2 figure 10-3