INSTALLATION GENERAL
IMPORTANT NOTES
THE JEWEL SUNRISE IS DESIGNED AND TESTED TO THE REQUIREMENTS OF
BSEN509:2000 AND IS FITTED WITH AN ATMOSPHERE SENSING DEVICE
THE JEWEL SUNRISE CAN ONLY BE USED IN CONJUNCTION WITH A
CONVENTIONAL CLASS 1 FLUE OR A 5” FLUE LINER WHEN INSTALLED WITH A
CRYSTAL FLUE SPIGOT SHOWN IN FIG a
A NON COMBUSTABLE HEARTH MUST BE PROVIDED TO COMPLY WITH THE
BUILDING REGULATIONS OR A SUITABLE PROPRIETARY FIRE SURROUND WITH A
100 DEGREES C RATING.
UNLESS INSTALLED 300mm ABOVE FLOOR LEVEL(SEE SEPARATE PAGE)
THE CHIMNEY OR FLUE(UNLESS NEW)MUST BE SWEPT BEFORE INSTALLATION IF
IT HAS BEEN USED FOR SOLID FUEL
* INSTALLER
THE APPLIANCE MUST BE INSTALLED BY A COMPETENT PERSON ,IE A CORGI
REGISTERED INSTALLER IN ACCORDANCE WITH THE CURRENT GAS
SAFETY(INSTALLATION AND USE)REGULATIONS 1994 OR THE RULES IN
FORCE.FAILURE TO DO SO COULD LEAD TO PROSECUTION
*REGULATIONS
THE FOLLOWING ARE THE RELEVANT CODES OF PRACTICE AND BRITISH
STANDARDS:
BS5781 PART 2 AND 3 1991 BS8303 1986 BS 5440 PART 1 1990 BS 6891
1988 BS 6461 PARTS 1 & 2 1984 BS 715 1989
THE BUILDING REGULATIONS ISSUED BY THE DEPARTMENT OF THE ENVIROMENT
THE BUILDING STANDARDS(SCOTLAND)(CONSOLIDATION)REGULATIONS ISSUED BY
THE SCOTTISH DEVELOPMENT OFFICE
*VENTILATION
GREAT BRITAIN
NO SPECIAL VENTILATION BRICKS OR VENTS ARE NORMALLY REQUIRED INTO
THE ROOM CONTAINING THE APPLIANCE,PROVIDED NORMAL ADVENTITIOUS ROOM
VENTILATION EXISTS. THE INSTALLER MUST SATISFY THIS POINT BY
CARRYING OUT A MANDATORY SPILLAGE TEST.
IRELAND
PURPOSE PROVIDED VENTILATION MUST BE PROVIDED AND MUST HAVE A
MINIMUM FREE AREA OF 100CM
2
*WARNING
THIS APPLIANCE HAS A NAKED FLAME,AS WITH ALL SUCH FIRES IT IS
RECOMMENDED THAT A FIREGUARD SHOULD BE USED FOR THE PROTECTION OF
CHILDREN,THE ELDERLY AND INFIRM.FIRE GUARDS SHOULD CONFORM TO BS
6539 (1984)(FIREGUARDS FOR USE WITH SOLID FUEL APPLIANCES).