background image

!

 

23

Hold  handset  and  press  and  release  the  mode  button  several  times  as  necessary  until  the  display  has  a 
thermometer symbol flashing at the top of the display. Press the set button to enter this mode. 
Press the set button again to see the temperature setting that is set and the mode  (the default is 24 C ) and 
on the left of the display is a sun symbol showing it’s the day temperature. 

If a different set temperature is required, while the display is showing this set temperature , press the + and 
– buttons to alter the setting. When finished either press set or leave and after a few seconds the new setting 
will be accepted and the display will return to the time of day screen. 

On  the  anniversary  of  the  net  minute  of  the  clock,  the  set  temperature  will  be  compared  to  the  actual 
temperature displayed on the handset(i.e. the room ambient temperature around the handset). If the room 
temperature is higher than the set temperature the fire will not light until the room has cooled to below the 
set  temperature.  The  fire  would  then  automatically  turn  itself  on  when  the  room  is  cooler  than  the  set 
temperature and down and off if necessary when it is hotter than the set temperature.  
(Note-    when  the  set  temperature  is  reached    while  the  fire  is  in  operation,  the  fire  reduces  the  burner 
power level each minute until the burner is off. The pilot (if fitted) will remain on for a further 30 minutes 
and if the set temperature is still too high , the pilot will then also extinguish. When the set temperature is 
higher than the actual temperature , the fire will automatically light and go to the full burner rate to reheat 
the room back to the set temperature.  

Note:  If  at  any  time  the  power  button  is  operated  during  Thermostat  mode,  the  control  will  cancel  any 
thermostat operation and return the control to manual mode. 

For  ease  of  setting  there  are  two  other  modes  that  can  be  selected  as  stated  above.  Night  mode  (moon 
symbol)  and  frost  protection  setting  (a  snow  flake). These  can  be  selected  (and  adjusted  if  necessary)  by 
pressing set then mode while in thermostat mode. Pressing mode button toggles through from day to frost 
modes.  The  purpose  of  these  settings  is  to  help  your  fire  to  automatically  protect  you  home  against 
becoming too cold if there is a sudden change in the weather. The control must be left in the appropriate 
mode for this to function. 
Note: As stated in an earlier section, snooze function can also be operated in conjunction with thermostat 
mode. The thermostat symbol and the Zzz symbol will be on together when in this mode. 
Thermostat mode for open fires 
This is the same as for closed fires except that :- 
The  fire  will  not  ignite  automatically  and  it  will  only  regulate  between  minimum  and  maximum  burner 
setting. The  fire  is  lit  manually  by  the  remote  control  and  then  you  enter  thermostat  mode  as  described 
above  and  set  the  temperature.  When  no  longer  requiring  thermostat  mode.  Turn  off  the  burner  as 
described above and the handset returns to manual mode. 

Summary of Contents for CONNELLY GAS STOVE

Page 1: ...LENTINES BUILDINGS AINTREE RACECOURSE BUSINESS PARK LIVERPOOL L9 5AY THIS APPLIANCE IS CATEGORY I2H FOR USE WITH NATURAL GAS AT A SUPPLY PRESSURE OF 20 mbar G B AND I E INSTALLATION SERVICING BOOK THI...

Page 2: ...NEY SUITABILITY 3 4 2 0 INSTALLATION 5 2 1 HEARTH 5 2 2 SITING 5 2 3 FLUE CONNECTION 5 2 4 VENTILATION 5 2 5 GAS CONNECTION 6 2 6 FUEL FITTING 7 8 2 7 OPERATING INSTRUCTIONS 9 10 11 12 2 8 SPILLAGE 13...

Page 3: ...and use regulations or the rules in force failure to do so could lead to prosecution The installer must be gas safe registered The installation must also be in accordance with all relevant parts of t...

Page 4: ...ensure that the inside of the chimney flue is in good condition along its length and check that there is no leakage of smoke through the structure of the chimney flue during and after the smoke pellet...

Page 5: ...ould be fitted for protection of young children or elderly or infirm persons The door handle has to be removed to remove the glass allow to cool before removing this as it will become very hot and is...

Page 6: ...tilation should be in accordance with national regulations in the UK purpose provided ventilation is not normally required BS5871 part 1 and in IE IS813 IE only 2 5 GAS CONNECTION The gas can be made...

Page 7: ...burner with the mica fill ensuring it is filled to top and evenly spread around Back log can be placed as shown to the left The left of the log to the end of the burner Large log sits into the left c...

Page 8: ...sits to the front on to the left As shown image left The triple branch log sits on the left side touching the very left side of the first log and the second log As shown to left Final log sits from f...

Page 9: ...9 Below remote control handset 2 7 OPERATING INSTRUCTIONS Below the gas controls which are situated at the bottom left of the appliance...

Page 10: ...et The handset also has batteries as shown below It is important that the batteries are replaced at least every 12 months The meaning s of the red indicator on valve and handset Red indicator Meaning...

Page 11: ...ote This button press must be done with 1 second of the red light coming on If not done quickly enough then the above must be repeated until done correctly When done correctly you will hear an audible...

Page 12: ...he power symbol button and release immediately when the word pilot comes on to the display at the bottom left as shown about 1 2 seconds The stove will light NOTE Releasing too soon or too long after...

Page 13: ...res used 3 0 SERVICING INSTRUCTIONS The stove is fitted with a spillage monitoring system consisting of a thermal switch this system is not adjustable and must not be bypassed or put out of action if...

Page 14: ...TOVE 1 VALENTINES BUILDINGS AINTREE RACECOURSE BUSINESS PARK LIVERPOOL L9 5AY THIS APPLIANCE IS CATEGORY I2H FOR USE WITH NATURAL GAS AT A SUPPLY PRESSURE OF 20 mbar G B AND I E USERS INSTRUCTIONS THI...

Page 15: ...ut must be in accordance with national regulations in force The fuel should be arranged only as shown in these instructions Should the stove extinguish for any reason do not relight for a minimum of 3...

Page 16: ...r with the mica fill ensuring it is filled to top and evenly spread around Back log can be placed as shown to the left The left of the log to the end of the burner Large log sits into the left corner...

Page 17: ...g sits to the front on to the left As shown image left The triple branch log sits on the left side touching the very left side of the first log and the second log As shown to left Final log sits from...

Page 18: ...18 OPERATING INSTRUCTIONS Below the gas controls which are situated at the bottom left of the appliance Below remote control handset Display handset may be supplied to assist seasonal efficiency...

Page 19: ...andset The handset also has batteries as shown below it is important the batteries are replaced every 12 months Red indicator Meaning Permanently Lit Valve tried to light but failed and in LOCKOUT E00...

Page 20: ...ote This button press must be done with 1 second of the red light coming on If not done quickly enough then the above must be repeated until done correctly When done correctly you will hear an audible...

Page 21: ...he power symbol button and release immediately when the word pilot comes on to the display at the bottom left as shown about 1 2 seconds The stove will light NOTE Releasing too soon or too long after...

Page 22: ...button and this will put the control into Manual snooze mode The default time period for the snooze time period is 1 00 hour Pressing the set button again will show you the snooze time period remainin...

Page 23: ...utes and if the set temperature is still too high the pilot will then also extinguish When the set temperature is higher than the actual temperature the fire will automatically light and go to the ful...

Page 24: ...next time of 09 00 press and release SET change the flashing sun symbol to a flashing moon symbol by pressing and releasing the and buttons then press and release SET again to store the moon setting...

Reviews: