13
2.8 SPILLAGE
CHECK FOR CLEARANCE OF COMBUSTION PRODUCTS
CLOSE ALL DOORS &WINDOWS IN ROOM CONTAINING APPLIANCE
TURN ON APPLIANCE AND TURN TO HIGH LEAVE RUNNING FOR 5 MINUTES AND INSERT A LIGHTED
TAPER OR SMOKE MATCH INTO THE FLUE DIVERTER AT THE REAR OF THE APPLIANCE
ALL THE SMOKE MUST BE DRAWN INTO THE APPLIANCE
IF SPILLAGE OCCURS ALLOW A FURTHER 10 MINUTES AND RETEST
SHOULD SPILLAGE OCCUR SEEK EXPERT ADVICE
IF AN EXTRACTOR FAN IS SITUATED IN THE ROOM THE TEST SHOULD BE CARRIED OUT WITH THE
FAN RUNNING IF THERE IS A CONNECTED ROOM WITH AN EXTRACTOR FAN THE TEST SHOULD BE
REPEATED WITH THE FAN RUNNING AND ANY INTERCONNECTING DOORS OPEN
2.9 CUSTOMER EDUCATION
Hand these instructions to the user
Advise the user until they are fully educated on the use of the stove and the controls
Explain regarding the thermal cut off feature
Advise if this system repeatedly shuts off specialist advice must be consulted
Advise that if the fire goes off for any reason do not re light for 3 minutes
Advise the stove may give off a slight smell due to the newness and any odors will go after a few hours of use
Advise that the stove must not be used with the glass panel damaged or broken or missing
Advise that no materials like washing, may not be draped over the stove
Recommend regular servicing at least annually
Recommend no extra fuel pieces are added and only authorised spares used
3.0 SERVICING INSTRUCTIONS
The stove is fitted with a spillage monitoring system consisting of a thermal switch this system is not
adjustable and must not be bypassed or put out of action if any parts are replaced it must be with the original
manufacturers parts used
1. Servicing must be carried out regularly and only by a qualified person, ensure the fire is turned off and
cold (minimum service must be carried out annually)
2. Open the stove door by unscrewing the handle on the left fully and remove the door can now be opened or
even lifted off its hinges then the nuts holding the glass can be removed and the glass panel removed
3. Remove the ceramics carefully
4. Remove any debris from the burner if necessary vacuum also clean the pilot or vacuum
5. If necessary replace pilot (for extended warranty) by removing burner and disconnect gas supply 4 screws
can be removed and burner tray removed the thermal cut off switch will have to be disconnected at the rear
of the fire to allow the tray to be removed it has to be lifted up on the right hand side and carefully twisted
out
6. Replace burner tray and reconnect thermal switch the appliance will not work if this is not done and then
replace in reverse order replace glass and stove door
7. Check the supply pressure and test for spillage
8. The flue will need sweeping periodically for safe use of the appliance
PILOT ASSEMBLY
ERTA-PG-82-330 A14
THERMAL SWITCH
TSC-30112010AFV
THERMAL SWITCH WIRES
TTB WIRES
FUEL
LOGS
INJECTOR
STEREOMATIC 500
HANDSET
TESC DISPLAYHANDSET
VALVE
TESCO1 RF868-15
3.1 REPLACEMENT PARTS