background image

CRT1081IRD-S2-MX

USER’s MANUAL

4.6.3 Program assignment to multiplexes

Fig. 16  Program assignment to multiplexes

Any program of the selected input can be assigned to one of four  CRT1081IRD-S2-MX output 

multiplexes. Only point the multiplex the program have to be distributed in. You can only map a program 
with only one multiplex. Press 

Save

 to store and apply remultiplexer configuration.

Note. After reset to the factory settings (4.3.2) your current configuration data will be lost.
         Export your current settings if you need them later.

Crypton, January 2013

21

Summary of Contents for CRT1081IRD-S2-MX

Page 1: ...CRT1081IRD S2 MX USER s MANUAL USER S MANUAL CRT1081IRD S2 MX Compact size 8 channel multiplexing DVB S2 IRD Crypton January 2013...

Page 2: ...PUT PAGE 4 3 1 Tuners setting up 13 4 3 2 Common Interface setting up for CAM descrambling 14 4 3 3 ASI input state monitor 15 4 4 ASI OUTPUT CONFIGURATION 4 5 DVB OVER IP CONFIGURATION 4 5 1 Device c...

Page 3: ...y configurable 8 channel Common Interface for descrambling services and 4 channel DVB remultiplexer with DVB EPG processor DVB ASI and DVB over IP outputs all in one 19 inch 1U case Such a compact and...

Page 4: ...channels 12 Number of output channels 4 Specifications ISO IEC 13818 1 Max output bitrate all channels On 300 Mbit s IP 400 Mbit s ASI PID restamping Yes SI PSI processing Yes DVB EPG server Yes embed...

Page 5: ...CRT1081IRD S2 MX USER s MANUAL Temperature 10 30 C Relative Humidity Up to 95 without condensation Dimensions Width mm 440 Depth mm 356 Height mm 44 Crypton January 2013 5...

Page 6: ...k do not operate equipment with the cover removed Repairs must be performed by qualified service personnel only Remember that voltages higher then 60 V DC or 30 V AC rms are dangerous 2 2 Device Safe...

Page 7: ...ice network factory settings RESET button 4 LEDs for tuners lock and CAM modules insertion indication 5 100Mbit Ethernet port for device control 6 Common Interface slots for CAM modules 3 1 2 Rear vie...

Page 8: ...uts ASI inputs and outputs 4 Connect the device Ethernet port to the same type port of the host PC with cross cord or use patch cord when Ethernet switch is used 5 Connect the power supply cord to an...

Page 9: ...t You can reset the device network setting and access rights to the default any time you need When the device is operating please carefully press IP RESET button on the front panel and hold for 1 2 se...

Page 10: ...ion with a web browser connected to the network to access the Web Interface to configure the unit for operation It is recommended to use the following list of current or later Browser versions Google...

Page 11: ...ch as Tuner ASI inputs IPE ASI outputs Service filter etc Use Logout button in the left up conner to disconnect the device from your PC Reboot is used to restart the device software Find language sele...

Page 12: ...tch high or low below 11700 MHz Ku Band frequencies LNB power If on 13 18v power up to 400 mA can be supplied to the LNB LNB polarization If other LNB type is selectet and LNB power is set ON 13 or 18...

Page 13: ...ors information Invert let you switch brief and expanded information modes Save used Save to apply and store new descrambling settings For scrambled programs all their CA_Descriptors are listed agains...

Page 14: ...4 3 3 ASI input state monitor CRT1081IRD S2 MX has four DVB ASI inputs that atomatically tune to proper operation mode You can see current ASI input interface state on the ASI input page Fig 7 ASI inp...

Page 15: ...rk ID DVB identifier of you broadcast network 0 to 65535 Please reffer to the latest version of DVB specification ETSI TS 101162 to select correct number Original Network ID DVB identifier the origina...

Page 16: ...net address space or multicast address 224 0 0 1 239 255 255 255 Port UDP port of the stream receiver 1 65535 State You can use this switch to stop or resume output TS cast streaming Status LINK ACTIV...

Page 17: ...stream processor no other programs can be got on the device outputs The following actions can be done Aquire stream service information independently for the selected input or for all inputs Select o...

Page 18: ...o interrupt The list off all programs on the Input Inputs appears every time PSI SI filtering is successfully finished Fig 12 Acqired Input TS information No signal massage shows that there is no reli...

Page 19: ...rs Fig 14 PSI information window Program name The name that program comes to the system with Provider Program provider information Program number Unique for the current transponder program number Sour...

Page 20: ...ed Service type Type of a service the selected program cosists of Pid Service ID Service descriptors List of descriptors for the current service Program descriptors List of descriptors for the current...

Page 21: ...CRT1081IRD S2 MX output multiplexes Only point the multiplex the program have to be distributed in You can only map a program with only one multiplex Press Save to store and apply remultiplexer confi...

Page 22: ...information of eatch multiplex Right after you save programs to multiplexes mapping information new edit option appears on the program filter page Click this new link to enter PSI SI edit window Fig...

Page 23: ...program Program descriptors List of descriptors of the edited program Don t change those descriptors if you are not sure you are really need it Unmark a descriptor if you want it to delet PID Service...

Page 24: ...tred first time An other delet option appears to remove program from the output interface Select action Let you select an action for a list of multiplex programs Note Any change on this page takes eff...

Page 25: ...d into the device Upload new data or download current data into information window to see the content Pig 21 EIT NIT tables are not uploaded to the device You can use EPGEditor and NITEditor service p...

Page 26: ...age Every time EIT data is uploaded you can see it in proper information window State On make the EIT information visible in the TS Status Shows if valid data present Note Please make sure system time...

Page 27: ...After NIT data are uploded to ther device proper information window shows current information State On Off let you stop or release network infomation injection Status Shows if correct data are uplodet...

Page 28: ...e the best if you use common network classes A B C Defaul IP address 192 168 0 100 is a class C address and usually sucsessfully interoperate with most of network equipments Always use correct subnet...

Page 29: ...ord Press Save to store new account settings Note For Login use only legal symbols a z A Z 0 9 _ Symbol register is applied Min Login lenth 1 symbol Max 32 Use following set of password symbols a z A...

Page 30: ...system time UTC offset is used for local time network operation You can also set Country Code and Country Region Daylight saving mode is also supported Fig 26 Date and Time setting up Note After power...

Page 31: ...upload to the device F W integrity check and current configuration back up F W download to the device volatile memory Fig 28 Upload new F W After you select F W file upload process start automatically...

Page 32: ...case you face sudden flashing problems Do Not power off the device and try to restart the process again Fig 30 New F W successfully downloaded To start CRT1081IRD S2 MX operate with new F W turn the...

Page 33: ...failure due to power off or connection loss F W recovery process starts automatically every time you turn the device power On after base device F W is damaged Fig 31 F W recovery page Select F W you h...

Page 34: ...ort data to the file and save it until reserve device is required or F W update is made Fig 32 Export and import of configuration data Note After configuration is imported to an other device it operat...

Reviews: