background image

 

CTL- Contactless Temperature Logger 

detailed user guide version 1.2 

Page 

31 

 

Simple and  Smart 

C T L   U S E R   G U I D E  

 

 

Details Full 

– Chart Full (Second Page) 

21 CFR 11 Enabled

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

                                

 

     Figure 21. Sample Report PDF Details Full - Chart Full and 21 CFR 11 Enabled (Second page)

 

 

Summary of Contents for Contactless Temperature Logger

Page 1: ...CRYOPAK VERIFICATION TECHNOLOGIES INC Contactless Temperature Logger Rev 1 2 ...

Page 2: ...y Drive PO Box 309 Buchanan VA 24066 USA Phone 540 254 1433 732 346 9200 Ext 150 Fax 540 254 2433 techsupport cryopak com 11000 Parkway Blvd Anjou QC Canada H1J 1R6 Canada Phone 514 324 4720 Fax 514 324 9623 support cryopak com 1 Rue Berthelot Z I La Maine 76150 Maromme France Phone 33 0 2 32 82 59 65 ordersEU cryopak com ...

Page 3: ...aring apps Dropbox Google Drive etc Contactless Temperature Data Logger Large memory capacity Utilizes mobile app Long battery life Pre programmed to customer specifications 7 LED indicators High accuracy Waterproof pouch The new Contactless Temperature Logger also known as just CTL is now available for storage and transit temperature monitoring solutions It is completely food safe with IP rating ...

Page 4: ... a loss of warranty All repairs are to be made by an official Cryopak Verification Technology service center The CTL Contactless Temperature Logger has a one trip warranty For more information refer page 16 Battery life depends greatly on the temperature environment and recording frequency of your CTL Contactless Temperature Logger Product Code The product code for CVT products is represented in a...

Page 5: ...O Single use Contactless logger 8K memory with beeper and RF always on Available in 2020 CTL ST 16 B RAO Single use Contactless logger 16K memory with beeper and RF always on Available in 2020 CTL IN 8 RAO Multi use Contactless logger 8K memory with no beeper and RF always on Available in 2020 CTL IN 16 RAO Multi use Contactless logger 16K memory with no beeper and RF always on Available in 2020 C...

Page 6: ...ff 3 4 seconds Start 7 9 seconds Stop 10 12 seconds Status Refresh Check status 2 seconds Battery Type CR2450 Panasonic 3 0V coin cell Size Dimensions 95mm x 50mm x 9mm with plastic sleeve Weight 20g IP Rating IP 67 Completely Food Safe Other certification CE ISO9001 2008 RoHS Shelf Life 1 Year Time Accuracy 5 hour per year Calibration points Calibration on customer request Program Option Pre prog...

Page 7: ...S Line of sight range Product label specifying product code and serial number plus bar coded serial number according to QR Code Five LED s displays temperature above or below specification depending on the set alarm conditions LOW LOW LOW OK HIGH and HIGH HIGH Two LED s display logger status and RF transmission status Start the logger via START button immediately or with mobile app Logging interva...

Page 8: ...que device number Example Cryopak RF 01 18 62 E4 3E 0E 89 According to the two permissions given through the initial part of app installation app will create a temp folder in internal shared storage of device that will contain all the downloaded PDF files of CTL Contactless Temperature Logger which are named with the serial number 18 62 E4 3E 0E 89 pdf LEDs CTL Contactless Temperature Logger has 7...

Page 9: ... Sec Stop Logging Push main button Short press HH High High Alarm temperature excursion above HH value H High Alarm temperature excursion between H and HH value OK No Alarm L Low Temperature Alarm temperature excursion between L and LL value LL Low Low Temperature Alarm temperature excursion below LL value Push Status Refresh button Short press HH Device is in Start Delay Period H Device is Loggin...

Page 10: ...ge 9 Simple and Smart C T L U S E R G U I D E Connection Communication 1 1 Download and install the CTL Contactless Temperature Logger from Google Play Store Figure 1 Figure 1 Download and Install the CTL Contactless Temperature Logger application from Google Play Store ...

Page 11: ...ect with CTL Contactless Temperature Logger Application Launch the CTL Contactless Temperature Logger Application in your device you will see main page of application Figure 2 It will ask you for two permissions to be able to save your CTL downloaded data in a folder in internal shared storage of user s device Figure 3 and 4 ...

Page 12: ...S E R G U I D E Figure 2 Open Application Main Page 1 3 Allow CTL application to have acces to files on the device for creating required folders and files in internal shared storage for reading and writing data Figure 3 Application Asks for permission to have access to Photos Media and files on device ...

Page 13: ...t C T L U S E R G U I D E 1 4 Allow CTL application to have acces to the device s location to be able to connect to the desired CTL Contactless Temperature Logger for programming or exporting recorded data Figure 4 Figure 4 Application asks for permission to have access to device s location ...

Page 14: ...T L U S E R G U I D E 1 5 Turning on the Bluetooth Once permissions are allowed the app will open and If the Bluetooth is not turned on it will ask to turn on Bluetooth so it can detect and connect to the CTL Contactless Temperature Logger Figure 5 Figure 5 Application asks to turn on Bluetooth ...

Page 15: ...1 2 Page 14 Simple and Smart C T L U S E R G U I D E 1 6 Once Bluetooth is connected the first page of application will appear and then application will be able to detect the online CTL Contactless Temperature Logger Figure 6 Figure 6 First page of CTL Application ...

Page 16: ...ets connected to the application Once the CTL Contactless Temperature Logger is turned on the application will search for online devices and detect it The name and serial number of the online device will appear on the main page of application Figure 7 Figure 7 Application Detects the online CTL Contactless Temperature Logger and shows the device name and serial number The Name and Serial number of...

Page 17: ...ature Logger with the device Figure 8 The Status LED will blink twice and the buzzer beeps twice The RF LED will get solid on once the CTL Contactless Temperature Logger is connected All the information s of that CTL Contactless Temperature Logger will appear on the screen once it connects Figure 9 Figure 8 Connect the CTL Logger to application Click on Connect button to connect to the CTL Contact...

Page 18: ...splay unit from Fahrenheit to Celsius Ping Ping the connected CTL Contactless Temperature Logger from application When pinging CTL Contactless Temperature Logger Status LED will blink twice while buzzer beeps Sync time Synchronize the Time of connected logger Buzzer will beep twice Start Manually start the CTL Logger Sleep Sleep mode will be activated immediately Buzzer beeps once Stop Stop the on...

Page 19: ... buzzer will beep twice during programming When the CTL Contactless Temperature Logger is programmed but not yet started the GREEN and the ORANGE RF LEDs will be on and after the RF Timeout sec it will go to sleep mode But in case that the user starts immediately by pressing the start button the CTL Contactless Temperature Logger will beep once and both LEDs will turn off then the Logger will star...

Page 20: ... generating alarm Seconds Rf Timeout CTL logger sleeps after Timeout Seconds Temp HH High High threshold Temp H High threshold Temp L Low threshold Temp LL Low Low threshold Audio Alarm set the audio alarm volume to have audio alert in case of alarm triggered Audio alarm may affect battery life Log Mode Full Data Log Events log Temp Log Data RF Always On CTL logger will connect to CTL App automati...

Page 21: ...e the Start Program is pressed the CTL Contactless Temperature Logger will be programmed with the parameters set in the previous step Figure 11 CTL application will show a pop up message confirmation of successful programming return to its first page Figure 13 Press Program Figure12 Program CTL Contactless Temperature Logger ...

Page 22: ...mperature Logger detailed user guide version 1 2 Page 21 Simple and Smart C T L U S E R G U I D E 1 13 Pop Up message of successful programming Figure13 Program confirmation pop up for CTL Contactless Temperature Logger ...

Page 23: ...c intervals If there is no alarm activated during entire logging period GREEN LED will blink until the end of the logging trip 1 16 Alarm The CTL Contactless Temperature Logger supports four alarm conditions if temperature goes out of specification then corresponding LEDs will start flashing during logging or when stopped Alarm Logger window LED LED color HIGH HIGH HH LED 1 RED LED HIGH H LED 2 RE...

Page 24: ...ing DATA Launch CTL app enable RF by pressing push button for 1 second If CTL Logger is programmed with the RF always On option activated there is no need to press the button once logger is detected press connect and then press download Figure 14 Figure14 Download Logged data from CTL Contactless Temperature Logger Press Download ...

Page 25: ...mmediately after the download is completed EXPORT page displayed now data can be exported in desired format to view and email for sharing Figure 15 Counter displays number of records downloaded Logger will beep until download finishes and status LED will flash RF LED will be solid Counter will display of records downloaded ...

Page 26: ...tatistics Brief Chart Details Full Chart Brief multiple pages report includes Device Specification Statistics Brief Chart Detailed Data Details Full Chart Full multiple pages report includes Device Specification Statistics Brief Chart Detailed Data with Chart Figure 16 Exporting DATA Press Export to export dowloaded Datas Compliance with FDA Title 21 CFR part 11 can be achieved by activating the o...

Page 27: ...uld be exported to be able to share or view it View File Once data is exported in desired format it can be viewed many times until new data is downloaded Share User can directly email the generated report by providing Email address in Email Address field Send to Mirador Downloaded data can be transferred to Mirador Express as offline data and report generation will be accessible through Mirador Ex...

Page 28: ... I D E Export Once data is exported in desired format it can be viewed at My Files Internal storage CTL directory Or immediately can be viewed and or exported in PDF or CSV format Sample PDF Details Brief Chart Brief 21 CFR 11 Enabled Figure 17 Sample Report PDF Details Brief Chart Brief and 21 CFR 11 Enabled ...

Page 29: ... Logger detailed user guide version 1 2 Page 28 Simple and Smart C T L U S E R G U I D E Details Full Chart Brief First Page 21 CFR 11 Enabled Figure 18 Sample Report PDF Details Full Chart Brief and 21 CFR 11 Enabled First page ...

Page 30: ...Logger detailed user guide version 1 2 Page 29 Simple and Smart C T L U S E R G U I D E Details Full Chart Brief Second Page 21 CFR 11 Enabled Figure 19 Sample Report PDF Details Full Chart Brief and 21 CFR 11 Enabled Second page ...

Page 31: ...re Logger detailed user guide version 1 2 Page 30 Simple and Smart C T L U S E R G U I D E Details Full Chart Full First Page 21 CFR 11 Enabled Figure 20 Sample Report PDF Details Full Cart Full and 21 CFR 11 Enabled First page ...

Page 32: ... Logger detailed user guide version 1 2 Page 31 Simple and Smart C T L U S E R G U I D E Details Full Chart Full Second Page 21 CFR 11 Enabled Figure 21 Sample Report PDF Details Full Chart Full and 21 CFR 11 Enabled Second page ...

Page 33: ...Temperature Logger detailed user guide version 1 2 Page 32 Simple and Smart C T L U S E R G U I D E Details Full Chart Full 21 CFR 11 Disabled Figure 22 Sample Report PDF Details Full Chart Full and 21 CFR 11 Disabled ...

Page 34: ... HH LED will start blinking H HIGH enable Triggers an alarm when the temperature is greater than the HIGH specification that has been recorded The H LED will start blinking L LOW enable Triggers an alarm when the temperature is lower than the LOW specification that has been recorded The L LED will start blinking LL LOW LOW enable Triggers raise an alarm when the temperature is lower than the LOW L...

Page 35: ... than 1 year after production or if the unit has been subject to environmental conditions outside those specified b Willful damage mistreatment misuse or abuse of the goods c Loss or damage caused by ingress of moisture unless ordered with immersion rating d Batteries e Circumstances where the unit has been modified from EVT specifications f Exposure of the logger to temperatures outside the speci...

Page 36: ...terials but others should not be disposed of in household waste To avoid pollution we kindly ask you to adhere to national policies and regulations concerning waste disposal and recycling CTL Contactless Temperature Logger pdf data loggers must be returned to your distributor for disposal European Standard EN 50419 2005 You can find additional information regarding all of our products on our websi...

Reviews: