Setting Tachometer Sensitivity
Five different values of tachometer sensitivity can be set using the Windows
software or on the MaxVu110 instrument itself. Press and hold the
$
and
"
"
"
"
"
keys for ten seconds to enter the Tachometer Sensitivity Editor (until you hear a
long beep). RPM will be shown on Display #1, the sensitivity value 1 to 5 on
Display #2 and the word “tACH” on Display #3 as shown in Figure 27. Quick
press the
%
or
$
key to decrease or increase the tachometer sensitivity. Press
the
&
key for 1 second (until the long beep) to accept the new value, save it to
memory and leave the Tachometer Sensitivity Editor mode.
Setting Tachometer Pulley Ratio
The tachometer can be rough calibrated to use a pulley ratio between 1:1 to
200:1 (for geartooth sensors) in seven steps. Final fine calibration is done on
the MaxVu110. Pulley Ratio cannot be set on the MaxVu110 itself and must be
done using the Windows configuration software
Clearing Trip Fuel , Trip Distance and Trip Time
Press and hold the
&
key for 10 seconds (until the long beep) to clear Trip
Fuel, Trip Distance and Trip Time logs to zero.
Figure 27 - Tachometer Sensitivity
Setting Tachometer Sensitivity to a
value of 1 to 5.