![Crown GLT-100 Installation & Operation Manual Download Page 4](http://html1.mh-extra.com/html/crown/glt-100/glt-100_installation-and-operation-manual_2690240004.webp)
INSTALLATION & OPERATION MANUAL 10325 REV 1 (11/21)
PAGE
4
OF 32
G
as
F
ired
S
team
T
ilting
K
ettles
S
ervice
C
onnections
S
ERVICE
C
ONNECTIONS
GAS CHARACTERISTICS
DIMENSIONS
* For use on non-combustible floors only.
SERVICE CONNECTIONS
– GAS CONNECTION: Supply Gas through 3/4” pipe. A gas shut off valve must be installed in supply piping convenient and adjacent to appliance.
– ELECTRICAL CONNECTION : Unless otherwise specified, field wire electrical connection to be 120 volts, 60 Hz, 1 phase with grounding wire. Unit
furnished with 8’ cord and 3 prong plug. Total maximum amps 4.0.
– COLD WATER: 3/8” (10 mm) tubing to faucet (optional)
– HOT WATER: 3/8” (10 mm) tubing to faucet (optional)
As continued product improvement is a policy of Crown, specifications are subject to changge without notice.
8971R0
IN [mm]
FLANGED FEET DETAIL
ON 2.835" [72mm] B.C.
Ø7/16" [11mm] HOLES
* Use on non-combustible floors only.
35.63 [905]
22.62 [575]
60.87 [1456]
4.26 [108]
10.76 [273]
5.38 [137]
30.81 [782]
43.81 [1113]
26.30 [668]
3" DRAW-OFF
VALVE
16.83 [428]
OPTIONAL
FAUCET
A
7.91 [201]
B
C
D
E
6.50 [165]
31.00 [787.4]
C H
C H
39.00 [991]
WATER LEVEL
PRESSURE
COOK TEMP.
LOW WATER
COOKING
POWER
OFF
ON
VE
NT
A
IR
20
100
psi
kPa
80
40
TUBE AND CONNECTION
200
0
100
316 SS
300
400
600
500
60
1
OFF
2
3
4
5 6
7
8
9
10
21.48 [546]
54.55 [1386]
43.83 [1113]
Model
Capacity
Units
A
B
C
D
E
Shipping Weight
Minimum Clearance
GLT-80
80 gallons
(302.8 liters)
in
(mm)
45.18”
(1147)
52.0”
(1321)
22.0”
(559)
89.63”
(2277)
25.38”
(645)
1253 lbs. [569 kg]
SIDES
BACK
0” [0 mm]
4” [102 mm]
GLT-100
30 gallons
(378.5 liters)
in
(mm)
49.8”
(1265)
54.5”
(1383)
23.5”
(597)
92.6”
(2353)
30”
(762)
1403 lbs. [637 kg]
Model
Gas Supply
BTU/HR.
kW/HR.
Supply Pipe Pressure (W.C.)
GLT-80/100
150,000
44.0
Natural
6”-14” (152-356 mm)
Propane
11”-14” (279-356 mm)