DriveCore Install Network Series
Power Amplifiers
Operation Manual
page 56
AC Power Draw and Thermal Dissipation
AC Power Draw and Thermal Dissipation:
Pink noise 12dB crest factor, bandwidth limited 22Hz to 22kHz.
Typical line impedance used.
Data based on all channels driven.
DCi 2
|
600N - Bridge
120 VAC / 60 Hz
230 VAC / 50 Hz
Condition
Load
"Line cur-
rent
(amps)"
Power Dissipated as Heat
"Line cur-
rent
(amps)"
Power Dissipated as Heat
watts
BTU
kcal/hr
watts
BTU
kcal/hr
At Idle Awake
N/A
0.6
71
241
61
0.4
66
226
57
1/8 Power
Pink Noise
Typical of program
material just at clip
4 ohms
1.4
90
308
78
0.8
91
311
78
8 ohms
2.2
101
344
87
1.2
101
344
87
16 ohms
2.1
94
321
81
1.1
92
314
79
140V
(16 ohms)
2.1
93
318
80
1.1
91
312
79
200V
(33.33 ohms)
2.0
86
295
74
1.1
84
287
72
1/3 Power
Pink Noise
Typical of program
material at
extreme clip
4 ohms
2.8
128
438
110
1.6
133
453
114
8 ohms
4.8
157
536
135
2.5
148
505
127
16 ohms
4.6
130
444
112
2.3
118
403
102
140V
(16 ohms)
4.6
125
427
108
2.3
117
399
101
200V
(33.33 ohms)
4.4
106
363
91
2.3
105
358
90
DCi 2
|
600N - Dual
120 VAC / 60 Hz
230 VAC / 50 Hz
Condition
Load
"Line cur-
rent
(amps)"
Power Dissipated as Heat
"Line cur-
rent
(amps)"
Power Dissipated as Heat
watts
BTU
kcal/hr
watts
BTU
kcal/hr
At Idle Awake
N/A
0.6
70
240
60
0.4
71
241
61
1/8 Power
Pink Noise
Typical of program
material just at clip
2 ohms
1.6
102
348
88
0.9
93
319
80
4 ohms
2.3
107
364
92
1.2
104
355
89
8 ohms
2.2
98
333
84
1.2
96
328
83
70V
(8 ohms)
2.2
96
329
83
1.2
94
322
81
100V
(16.67 ohms)
2.0
87
297
75
1.1
87
298
75
1/3 Power
Pink Noise
Typical of program
material at
extreme clip
2 ohms
3.0
142
486
122
1.6
134
456
115
4 ohms
4.8
161
549
139
2.5
153
521
131
8 ohms
4.5
131
446
112
2.4
129
441
111
70V
(8 ohms)
4.5
130
442
111
2.3
122
417
105
100V
(16.67 ohms)
4.5
122
417
105
2.4
109
370
93
Summary of Contents for DCi 2 300N