CAUTION!!!
Hot Surfaces: Keep children away. Do not touch during operation.
ALL INSTALLATIONS AND OPERATIONS MUST FOLLOW FEDERAL, PROVINCIAL, STATE, AND LOCAL CODES FOR
WIRING, PLUMBING, INSTALLING CHIMNEY. ALL WORK MUST BE PERFORMED BY QUALIFIED PERSONAL ONLY.
Chimneys
The size and height all depends on the unit you have purchased and where the unit will be located. Please refer to the
HPBA guidlines for smoke dispersal and recommended chimney heights on page 35 of this manual.
Contact your local dealer or Greentech Manufacturing, Inc for chimney purchase information.
• Installation of complete chimney flue is required.
• Adhere by local building codes and the National Fire Protection Association Rules Nos 31, 54 and 211.
• It is required to use Selkirk Chimney Systems, brand type is UT (Ultra Temp or Galva Temp)
• Selkirk Chimney Systems is a double insulated, stainless steel, Class A Chimney Systems that meets the
requirements of UL103 and ULC-S629 and complies with the Chapter 11 of NFPA 211, Standard for chimneys,
Fireplaces, Vents and Solid Fuel Burning Appliances.
• Chimney termination caps are required, installation of spark arresters may be needed in high fire risk areas.
• Selkirk chimney come in carious lengths, spanning from eighteen (18) inches to forty eight (48) inches. Install
each section of piping by placing male and female sections together then twisting them to lock sections
together. When installing your chimney piping, it is recommenced by many chimney suppliers to brace every
eight feet. Also recommended by the chimney manufacture that the height of the pipping does not exceed a
total of forty 40 ft.
• When installing chimney please refer to manufactures recommendations and requirements for adequate
clearances.
• Furnaces come standard with the Selkirk brand, 6”, 8”, or 10” Anchor plate as well as a 18” chimney length.
• Additional chimney components and lengths are available from your local dealer or can be purchased direct
from Greentech Manufacturing Inc. (Toll Free 866-361-7355)
• Do not attempt to fabricate your own adapters.
• Do not mix Selkirk Chimney with other manufactured brands.
• Do not use existing chimney that already connects to other appliance.
• A major cause of chimney-related fires is failure to maintain required clearances (air spaces) to combustible
material. It is of the utmost importance that the chimney be installed only in accordance with the manufactures
stated instructions. These instructions must be reviewed prior to installation of venting components.
• Inspections of chimney need to be preformed at least annual to ensure of any obstructions due to creosote
build up. When necessary preform cleaning of chimney to prevent chimney fires.
WARNING!!!
This unit can not be hooked to a chimney already serving another appliance.
CHIMNEY
WARNING!!!
Risk of Fire: Do not operate with fuel loading door, heat exchanger door or secondary combustion
door and/or ash removal doors open. Do not store fuel or other combustible materials within marked
installation clearances. Inspect and clean flues and chimney regularly.