![Crown Food Service Equipment ECTRS-16 Installation And Operation Manual Download Page 5](http://html1.mh-extra.com/html/crown-food-service-equipment/ectrs-16/ectrs-16_installation-and-operation-manual_2690674005.webp)
INSTALLATION AND OPERATION MANUAL,
ROUND ELECTRIC COUNTER TILTING SKILLET, MODEL ECTRS-16
PART NUMBER 10088R1
5
2005-02-14
2.0 INSTALLATION
1.
Position appliance on counter allowing sufficient rear clearance from wall to tilt freely and
completely without obstruction.
2.
Mark four corner locations of appliance base, as shown below.
3.
Remove appliance from counter and locate position of four holes as per drawing below.
Drill four 7/16" diameter holes.
4.
Apply a continuous bead of Silastic or other equivalent sealant along the complete
perimeter edge of the appliance base.
5.
Use 5/16-18 Hex Cap Screws with suitable flat washer to bolt down. Screw length must be
1-1/4 long plus counter top thickness.
6.
Wipe off excess sealant.
7.
A Control Box with power supply equivalent to Electrical Rating of appliance should be
located conveniently nearby.
8.
A waterproof electrical connection for power supply to console housing must be provided.
9.
Ground appliance to terminal provided inside console housing.
10. Turn power ON and check for proper operation.
Figure 1