![Crowcon Q-Test User & Operator Manual Download Page 23](http://html1.mh-extra.com/html/crowcon/q-test/q-test_user-and-operator-manual_2689469023.webp)
23
Gas
Gas Name
Recommended
Minimum
Concentration
Recommended
Concentration
Recommended
Maximum
Concentration
O
3
Ozone
0.7ppm
(concentration from
recommended
generator)
0.7ppm
(concentration from
recommended
generator)
≤ 0.7ppm
(concentration from
recommended
generator)
CL
2
Chlorine
≤ 1ppm
2.5ppm
≤ 3ppm
CLO
2
Chlorine Dioxide
≤ 0.5ppm
0.5ppm
≤ 0.8ppm
i
For a bump fail calibration certified gas to ±2% accuracy is recommended.
i
Ensure the accuracy of the gas cylinder used does not allow the nominal gas
concentration of the gas applied, to exceed the recommended maximum value.