Unload running speed is too low 

Adjuster pole location is incorrect 

Adjust

step on the gas

 

There are air interfused the fuel pipe 

Let out the air 

Large Shake 

Anti- shake feet was not Tighten 

Tighten 

Generator was not tighten 

Tighten 

Noise 

Engine Noise 

Repair 

Generator 

Bad bearing 

Replace 

Loose fasten screw 

Fasten 

Cover Noise 

Repair 

Over heat 

Check the enviornment 

Get rid of objects 

surrounded 

Wrong voltage 

Short circuit when loading 

Check 

Abnormal rotate speed 

Adjust rotate speed to 

rated value 

Rotor cable short circuit 

Repair 

Engine cable burning 

Repair 

Can not reach the rated 

voltage 

Over load 

Reduce loading to rated 

value 

Low rotate speed 

Adjust accelerograph to 

rated speed 

Generator cable burning 

Repair 

Low rotate speed 

Increase the rotate 

speed 

The length of cable between 

generater and loading is too long 

or the section of cable is too 

small 

Adjust fix position 

toshorten the distance, 

and oversticking the 

cable dia. 

Voltage drops when loading 

Main winding and the winding are 
burned 

Replace motor 

Overload 

Reduce loading to rated 

power 

Welding winding is burned 

Replace motor 

Welding current is abnormality 

Running speed is too low 

Adjust the accelerograph 

and increase the running 

speed 

 

 

 

 

 

 

 

Summary of Contents for 190CUB

Page 1: ...190CUB GASOLINE WELDING GENERATOR OPERATOR S MANUAL Operation Manual...

Page 2: ...ma torch parts nozzle electrode diffuser cover are considered consumable items and are not covered under warranty 90 days Parts for Crossfire spool guns welding carts and welding cabinets This warrant...

Page 3: ...Operator s self protection 2 3 Operator s notice 2 4 Safe Measures to be taken to assure the correct Installation and Position 2 5 Safety Check 3 Technical Specification 3 1 Environment to Which the...

Page 4: ...engineering and also could be applied to enterprise and public institution CUB 190 Gasoline welding generator function features 1 Power output 115 230V 60Hz 2 2KW 2 Welding current 55A 190A 3 Electrod...

Page 5: ...ammable materials at least 11 meters Prevent sparks to cracks or shady place Fire extinguisher should be allocated at working area No welding sealed vessel Acid liquor in battery may cause textile to...

Page 6: ...body without insulation No welding vessel with flammable and explosive materials or sealed vessel No operating at very humid filed Prevent flying sparks from hurting people No touching on any positio...

Page 7: ...ng machine Make sure that there is no interference with the surrounding area at the installation site Take measures to prevent wind while operating in the strong wind since the welder is gas shielded...

Page 8: ...l a u n a M e p y t g n i t r a t S g n i k r o w s u o u n i t n o c s r u o h 8 e p y t k r o W Gasoline generator 0 4 4 H C r e l h o K l e d o M r e d n i l y c e l g n i S e p y T fan cooled fou...

Page 9: ...el 4 1 Control panel parts name and function Item Name Qty Function 1 Start handle 1 Start engine refer to engine manual 2 Fuel tank cap dipstick 2 Fuel charging and fuel quantity measurement 3 Engine...

Page 10: ...mained quantity of fuel 11 Fuel tank cover 1 Fuel tank cover 4 2 Control Panel Drawing 1 5 Operation environment 5 1 Outdoor operation 5 1 1 The welder must be loaded in the place where less dust 5 1...

Page 11: ...d be reliably grounding 6 5 Check to make sure no oil leakage If leaking please contact us or seller immediately 6 6 Check whether the parts are loose Check and make sure not loosen of bolts nuts and...

Page 12: ...or operation 10 1 Prepare machine and all relative work 10 2 Choose correct welding cable and connect the power supply Connecting lug and terminal must be reliable in case of poor contact burning Cabl...

Page 13: ...e table 3 Besides Daily check others by hour Regular check is important to gasoline engine function and lifetime Check items and agenda as below check and clean Replace Table 3 Note means check should...

Page 14: ...filter is blocks up Clean or replace Take off the air is bad Let out the air Fuel cylinder type winding not working Examine the fuse If it breaks off please replace a new one Check and replace the cy...

Page 15: ...Rotor cable short circuit Repair Engine cable burning Repair Can not reach the rated voltage Over load Reduce loading to rated value Low rotate speed Adjust accelerograph to rated speed Generator cab...

Page 16: ...p e c e r k c o l t s i w t V 0 3 2 5 1 2 e l c a t p e c e r V 5 1 1 6 1 2 r e k a e r b t i u c r i C 7 1 1 r e k a e r b t i u c r i C 8 1 2 r o t c e n n o c k c i u Q 9 1 1 r o t s i s e R 0 2 1...

Page 17: ...y ventilation and free from corrosive gas or dust The tolerable temperature ranges from 25 with no cooling water 55 and the relative humidity can not be more than 85 17 Quality Guarantee Users are adv...

Page 18: ...16 Drawing 2 Main circuit chart...

Reviews: