Cross Technologies 4116-T21-310212 Instruction Manual Download Page 3

MODEL 4116-T21-310212 Translator, Weather Resistant

*

1.0  General

1.1  Equipment Description

The 4116-T21-310212 Translator converts a 29.0 - 30.0 GHz input RF band to 19.2 - 20.2 GHz or a 30.0 - 31.0 
GHz input RF band to 20.2 - 21.2 GHz. Front panel LEDs provide indication of DC Power, and PLL Alarm. 
The RF to RF  gain is +23 dB, maximum. Connectors are 2.92 mm female for the RF out, RF in and SMA 
female for the external reference input and reference output. Gain, band select, and internal 10 MHz frequency 
are controlled by the Ethernet M&C or via the Status/Control connector. In AUTO, the 10 MHz reference stays 
in external if the external level is in the +2 to +8 dBm range. It is powered by a 100-240 ±10% VAC power 
supply, and mounted in a 8” W X 6” H X 16” D Weather Resistant* enclosure.   

(NOTE: *Weather Resistant enclosures are designed to be water resistant for installation in an outdoor enclosure/antenna hut OR 

mounted outdoors on an antenna assembly at their specified temperature ranges.  They are designed to be located “out in the elements” 

(water, sleet, snow, etc.) but they are not designed to be “submerged under” water.  If an extended temperature range is required, there 

is an Extended Temperature option (Option W21; -30˚C to +60˚C) available at an additional cost.  Contact Cross for quote.

10M IN

STATUS / 

CONTROL 

ETHERNET

POWER

ALARM

J3

J4

10M OUT

FUSE

AC IN

F1

MODEL 4116 TRANSLATOR

RF IN

J1

.

.

.

C

ROSS

 

T

ECHNOLOGIES INC.

..

....

.....

....

...

.

RF OUT

J5

.

J6

J7

J8

Model 4116-T21-310212  Multi-Band Translator, Front Panel

4116-T21-310212 Translator Block Diagram

V
A
R

A
T
T

  RF Out
-20 to 0 dBm

19.2 to 20.2  
 GHz or
 20.2 to 21.2 
 GHz 

19.0 to 22.0 GHz BP 

 RF In
-40 to -20 dBm 

29.0 to
30.0 GHz or
30.0 to
31.0 GHz 

Band 1- 9.80 GHz
Band 2- 9.80 GHz

FIGURE 1     Model 4116-T21-310212 Multi-Band Block Translator Block Diagram

4116-T21-310212 Manual, Rev. 0

 

    

     Page 3

    

                   03/13/18  

Summary of Contents for 4116-T21-310212

Page 1: ...ithout the prior permission of Cross Technologies Inc for purposes of operating the equipment Printed in USA When ordering parts from Cross Technologies Inc be sure to include the equipment model numb...

Page 2: ...ctive materials and workmanship for a period of one year after shipment to customer Cross Technologies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s optio...

Page 3: ...s are designed to be water resistant for installation in an outdoor enclosure antenna hut OR mounted outdoors on an antenna assembly at their specified temperature ranges They are designed to be locat...

Page 4: ...dB max 20 to 0 dB variable in 1 1 dB steps Input to Output Isolation 45 dBC min 60 dBC typ at max gain and 0 dBm out Spurious Inband 30 dBC in band except 25 dBC 30 dBC typ at 20 dBm in for harmonics...

Page 5: ...t Connector Clipper Series CL1M1102 Mating Cable Connector CL1F1101 Unless otherwise specified the mating connector is provided preassembled onto a standard NEMA 5 15 U S power cord Weather Resistant...

Page 6: ...d CL101021 Backshell Pin Input Connector Pin Description 1 100 240 10 VAC 47 63 Hz 20 watts max 2 Neutral 3 Ground 2 1 Message Protocol The serial format for the RS232 RS422 RS485 port is 9600 baud 8...

Page 7: ...erence offset Range 00 to 31 xx 2 characters where aaCRxx Set RS485 address x 0 to unmute the output x 3 to select Auto 10 MHz reference x 1 to mute the output where aaCMx Set Mute x 2 to select RS485...

Page 8: ...nt gain setting is 14 0 dB x 3 if Auto 10 MHz reference is selected x 2 if External 10 MHz reference is selected x 1 if Internal 10 MHz reference is selected Returns aaSEx where aaSE 10 MHz reference...

Page 9: ...y 0 if unit is using internal 10 MHz ref y 1 if unit is using external reference x 0 if no summary alarm x 1 if summary alarm Returns aaSAxy where aaSA Unit Status Range 2000 to 2000 xxxxx 5 character...

Page 10: ...to the LAN using a normal RJ 45 cable Use any PC on the LAN to connect to the 4116 T21 310212 2 4 2 Ethernet Configuration Each 4116 T21 310212 must be configured with an appropriate IP address Netmas...

Page 11: ...teway address with delimiter dots example 192 168 192 47 2 4 3 Webpage M C Enter the following address in a web browser to access the M C webpage http ip address of 41xx serial 0 setup htm where ip ad...

Page 12: ...g Windows XP s Hyper Terminal utility Start the Hyper Terminal application and select New Connection from the File drop down menu The next screen is a Connect To dialog box Select TCP IP Winsock from...

Page 13: ...P community read and write strings After setting your desired community strings you will be prompted to Enter IP addresses for SNMP traps You must enter at least one and up to four IP addresses of SNM...

Page 14: ...Figure 2 F Device Server Configuration Menu 4116 T21 310212 Manual Rev 0 Page 14 03 13 18...

Page 15: ...T MODEL 4116 TRANSLATOR CROSS TECHNOLOGIES INC POWER IN AC input for switching power supply 100 240 10 VAC 47 63 Hz Weatherized CL1F1101 Connector POWER LED GREEN indicates when DC voltage is present...

Page 16: ...Connector Monito Monitor and Control Connector Pinout Conne Connector part number MS3112E14 18S Mating Mating Cable Connector part number MS3116F14 18P Pin Signal Description A Chassis Ground N Summa...

Page 17: ...is connected to J2 or EXT for external 10 MHz 2 to 8 dBm ref that is inserted at J2 via Ethernet or serial command See Table 2 0 and 2 5 1 8 Check that a 10 MHz signal is present at the 10 MHz REF OU...

Page 18: ...C 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com Printed in USA 4116 T21 310212 Manual R...

Reviews: