Cross Technologies 4116-T21-310212 Instruction Manual Download Page 2

INSTRUCTION MANUAL

MODEL 4116-T21-310212 Multi-Band Translator, Weather Resistant

TABLE OF CONTENTS   

PAGE

Warranty

2

1.0 General

3

1.1  Equipment Description

3

1.2  Technical Characteristics

4

2.0 Installation

6

2.1  Message Protocol

7

2.2  M&C Commands

 7 

2.3  M&C Queries

8

2.4  Ethernet Interface Installation

10

       

2.4.1  Methods of Connection

 10 

       

2.4.2  Ethernet Configuration

10

             

2.4.3  Webpage M&C

12

2.4.4  SNMP Configuration

12

2.5  Translator Outline Drawings

15

2.6  Physical Interface

16

2.7  Installation/Operation

17

WARRANTY - The following warranty applies to all Cross Technologies, Inc. products.

All Cross Technologies, Inc. products are warranted against defective materials and 
workmanship for a period of one year after shipment to customer.  Cross Technologies, 
Inc.’s obligation under this warranty is limited to repairing or, at Cross Technologies, Inc.’s 
option, replacing parts, subassemblies, or entire assemblies.  Cross Technologies, Inc. shall 
not be liable for any special, indirect, or consequential damages.  This warranty does not 
cover parts or equipment which have been subject to misuse, negligence, or accident by the 
customer during use.  All shipping costs for warranty repairs will be prepaid by the 
customer.  There are not other warranties, express or implied, except as stated herein.

C

ROSS 

T

ECHNOLOGIES, INC.

6170 Shiloh Road

Alpharetta, Georgia 30005

(770) 886-8005  •  FAX (770) 886-7964  •  Toll Free 888-900-5588

WEB www.crosstechnologies.com  •  E-MAIL [email protected]

4116-T21-310212 Manual, Rev. 0

 

    

     Page 2

    

                   03/13/18  

Summary of Contents for 4116-T21-310212

Page 1: ...ithout the prior permission of Cross Technologies Inc for purposes of operating the equipment Printed in USA When ordering parts from Cross Technologies Inc be sure to include the equipment model numb...

Page 2: ...ctive materials and workmanship for a period of one year after shipment to customer Cross Technologies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s optio...

Page 3: ...s are designed to be water resistant for installation in an outdoor enclosure antenna hut OR mounted outdoors on an antenna assembly at their specified temperature ranges They are designed to be locat...

Page 4: ...dB max 20 to 0 dB variable in 1 1 dB steps Input to Output Isolation 45 dBC min 60 dBC typ at max gain and 0 dBm out Spurious Inband 30 dBC in band except 25 dBC 30 dBC typ at 20 dBm in for harmonics...

Page 5: ...t Connector Clipper Series CL1M1102 Mating Cable Connector CL1F1101 Unless otherwise specified the mating connector is provided preassembled onto a standard NEMA 5 15 U S power cord Weather Resistant...

Page 6: ...d CL101021 Backshell Pin Input Connector Pin Description 1 100 240 10 VAC 47 63 Hz 20 watts max 2 Neutral 3 Ground 2 1 Message Protocol The serial format for the RS232 RS422 RS485 port is 9600 baud 8...

Page 7: ...erence offset Range 00 to 31 xx 2 characters where aaCRxx Set RS485 address x 0 to unmute the output x 3 to select Auto 10 MHz reference x 1 to mute the output where aaCMx Set Mute x 2 to select RS485...

Page 8: ...nt gain setting is 14 0 dB x 3 if Auto 10 MHz reference is selected x 2 if External 10 MHz reference is selected x 1 if Internal 10 MHz reference is selected Returns aaSEx where aaSE 10 MHz reference...

Page 9: ...y 0 if unit is using internal 10 MHz ref y 1 if unit is using external reference x 0 if no summary alarm x 1 if summary alarm Returns aaSAxy where aaSA Unit Status Range 2000 to 2000 xxxxx 5 character...

Page 10: ...to the LAN using a normal RJ 45 cable Use any PC on the LAN to connect to the 4116 T21 310212 2 4 2 Ethernet Configuration Each 4116 T21 310212 must be configured with an appropriate IP address Netmas...

Page 11: ...teway address with delimiter dots example 192 168 192 47 2 4 3 Webpage M C Enter the following address in a web browser to access the M C webpage http ip address of 41xx serial 0 setup htm where ip ad...

Page 12: ...g Windows XP s Hyper Terminal utility Start the Hyper Terminal application and select New Connection from the File drop down menu The next screen is a Connect To dialog box Select TCP IP Winsock from...

Page 13: ...P community read and write strings After setting your desired community strings you will be prompted to Enter IP addresses for SNMP traps You must enter at least one and up to four IP addresses of SNM...

Page 14: ...Figure 2 F Device Server Configuration Menu 4116 T21 310212 Manual Rev 0 Page 14 03 13 18...

Page 15: ...T MODEL 4116 TRANSLATOR CROSS TECHNOLOGIES INC POWER IN AC input for switching power supply 100 240 10 VAC 47 63 Hz Weatherized CL1F1101 Connector POWER LED GREEN indicates when DC voltage is present...

Page 16: ...Connector Monito Monitor and Control Connector Pinout Conne Connector part number MS3112E14 18S Mating Mating Cable Connector part number MS3116F14 18P Pin Signal Description A Chassis Ground N Summa...

Page 17: ...is connected to J2 or EXT for external 10 MHz 2 to 8 dBm ref that is inserted at J2 via Ethernet or serial command See Table 2 0 and 2 5 1 8 Check that a 10 MHz signal is present at the 10 MHz REF OU...

Page 18: ...C 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com Printed in USA 4116 T21 310212 Manual R...

Reviews: