1.3 Monitor & Control Interface
The following tables summarize the commands and status queries applicable to the
3116-T71 Multi-Band Translator
.
*
PLEASE NOTE:
The two character {aa} prefix, shown in the table below, is present ONLY when RS485 is selected.
Table 2.0 Model 3116-T71 M&C Commands
(NOTE: applies to currently selected band)
-500
≤
xxxxx
≤
0 for band 7
xxxxx = 0 for band 6
-260
≤
xxxxx
≤
300 for band 5
0
≤
xxxxx
≤
1000 for band 4
-1000
≤
xxxxx
≤
0 for band 3
xxxxx = 0 for band 2
-400
≤
xxxxx
≤
600 for band 1
where:
{aaCFxxxxx}
Set Frequency Offset
-2000
≤
xxxxx
≤
+2000
where:
{aaCOxxxxx}
Set Reference Offset
x = 3 for auto-select
x = 2 to select external reference
x = 6 to select band 6: in = (17.3 to 18.4 GHz)
Out = (10700 to 11800 MHz)
x = 5 to select band 5: in = (13.75 to 14.85 GHz)
Out = (11700 to 12800 MHz)
x = 1 to select internal reference
where:
{aaCEx}
Set External Reference
x = 0 to unmute the output
x = 1 to mute the output
where:
{aaCMx}
Set Mute
Range: -40 to +20 in 0.5 dB steps (e.g., +115 = 11.5dB)
xxxx = 4 characters
where:
{aaCGxxxx}
Set Gain
{aaCBx}
Set Frequency Band
x = 1 to select band 1: in = (5.85 to 6.95 GHz)
out = (3400 to 4500 MHz)
x = 7 to select band 7: in = (17.3 to 18.4 GHz)
Out = (11700 to 12800 MHz)
x = 4 to select band 4: in = (13.75 to 14.85 GHz)
out = (11700 to 12800 MHz)
x = 3 to select band 3: in = (13.75 to 14.85 GHz)
out = (10700 to 11800 MHz)
x = 2 to select band 2: in = (7.90 to 8.40 GHz)
out = (7250 to 7750 MHz)
Description
Syntax
Command
Table 2.0: Model 3116-T71 M&C Commands