2.6.6 Alarm Indications
An alarm condition will occur if the local oscillator phase lock loop (PLL) comes out of lock. The Mute LED
will light if you select to mute the Tx Signal and the Remote LED will light when you select the Remote mode.
ON POWER UP
NORMAL DISPLAY
PUSHING MENU/EXECUTE SEQUENCE
FPC 4.00
Load Settings...
PUSH BUTTON
B1 5.850 -> 3.400 GHz
G=10 TRANS = 2.050 GHz
Power Up
Normal Display
Menu 1 Set Band
Menu 2 Set Gain (-40 to +20 dB)
Menu 3 Mute TX signal
Menu 4 Frequency Offset
Menu 5 Select 10 MHz
Reference Mode
(Internal, External, Auto)
Menu 6 Reference
Frequency Offset
Menu 7 Select Secondary
Communications Interface
(Option Q)
Menu 8 Interior Temperature
Save Settings? At the end or
when “R” is selected from any of
the above menus
TEMP = +30C
SCROLL <>
PUSH BUTTON
BAND = 3
SCROLL <>
SCROLL
PUSH BUTTON
R
G = +10
SCROLL <>
SCROLL
PUSH BUTTON
R
MUTE OFF
SCROLL <>
SCROLL
PUSH BUTTON
R
FREQ OS = +0000
SCROLL <>
SCROLL
PUSH BUTTON
R
REF OS = +0000
SCROLL <>
SCROLL
PUSH BUTTON
R
PUSH BUTTON
COMM INTERFACE
RS232
SCROLL <>
SCROLL
PUSH BUTTON
R
REF MODE = INT
SCROLL <>
SCROLL
PUSH BUTTON
R
SAVE SETTINGS? Y N
R
SCROLL <>
SCROLL
PUSH BUTTON
FIGURE 2.5 Menu Display and Sequence
3116-T71 Manual, Rev. C
Page 19
10/01/2015