Table 2.0 Model 3116-66T42 M&C Commands
(continued)
x = 1 if the reference is on external
x = 0 if the reference is on internal
Returns {aaSBx} where:
{aaSB}
10 MHz reference status
yyyy = unit firmware rev.
x = 0 if no summary alarm, x = 1 if summary alarm
xxxxx is a signed number representing the ref. offset value
Returns {aaSOxxxxx} where:
{aaSO}
Reference Offset
xxxxxxxx = unit model number
Returns {aaSVxxxxxxxxyyyy} where:
{aaSV}
Model and firmware revision
Returns {aaSAx} where:
{aaSA}
Unit Status
x = 2 if in auto-select mode
x = 1 if External 10 MHz reference is selected
x = 0 if Internal 10 MHz reference is selected
Returns {aaSEx} where:
{aaSE}
10 MHz reference
Range: (-200 to -500 in 0.5 ±0.5 dB steps)
xxxx = 4 characters
Returns {aaSGxxxx} where:
{aaSG}
Gain
Description
Syntax
Command
Table 2.0: Model 3116-66T42 M&C Commands (continued)
3116-66T42 Manual, Rev.0
Page 7