B) Status Requests -
Table 1.1 lists the status requests for the 3116-192 and briefly describes them.
* PLEASE NOTE: The two character {aa}(00-31) prefix, in the table below,
should be used ONLY when RS-485 is selected.
TABLE 1.1 3116-192 Downconverter Status Requests
TABLE 1.1 3116-192 Downconverter Status Requests
TABLE 1.1 3116-192 Downconverter Status Requests
Command
Syntax *
Description
Get Gain
{aaSG}
returns {aaSGxxx} where:
• xxx = Converter gain in 0.5 ±0.5 dB steps.
Get Internal 10 MHz Reference Offset
{aaSO}
Returns {aaSOxxxxx} where:
• xxxxxx = Internal 10 MHz reference frequency offset.
Get 10 MHz Reference Mode
{aaSE}
Returns {aaSEx} where:
• x = 0 if the converter's 10 MHz reference mode is set to Internal
• x = 1 if the converter's 10 MHz reference mode is set to External
• x = 2 if the converter's 10 MHz reference mode is set to Auto
Get Mute
{aaSM}
Returns {aaSMx} where:
• x = 0 if the converter's RF output is NOT muted (RF output is ON)
• x = 1 if the converter's RF output is muted (RF output is OFF)
Get 10 MHz Reference Status
{aaSB}
Returns {aaSBx} where:
• x = 0 if the currently selected 10 MHz reference is Internal
• x = 1 if the currently selected 10 MHz reference is External
Get Summary Alarm Status
{aaSA}
Returns {aaSAx}where:
• x = 0 when there is no summary alarm condition
• x = 1 if there is a summary alarm condition
Get IP Address
{Si}
Returns {Sixxx.xxx.xxx.xxx} where:
Ethernet Option Only
• xxx.xxx.xxx.xxx = IP address
Get Subnet Mask
{Ss}
Returns {Ssxxx.xxx.xxx.xxx} where:
Ethernet Option Only
• xxx.xxx.xxx.xxx = subnet mask
!
Get Product/Model info
!!
{Sv}
Returns {Sv3116-192y..yverZZZZ} where:
• 3116-xx is the product model number
• y..y = list of options, if any
• '"ver" = separates model & options from firmware version
• ZZZZ = firmware version (e.g., 1.00)
3116-192 Manual
Page 7
12/02/21