C) Status Requests - Continued...
*
PLEASE NOTE: The two character {aa}(00-31) prefix, in the table below,
should be used ONLY when RS-485, (OPTION-Q), is selected.
Table 1.2 3016-1520-1200 SStatus
3016-1520-1200
Status Requests/Inqquiries
Table 1.2 3016-1520-1200 Status Requests/Inquiries
Command
Syntax
Description
Get product/model info
{aaSV}
returns {aaSV3016-1520-1200rev.5xx}
where:
aa = unit address, range = 00 to 31, only used if interface
is RS485, otherwise omit
V = command code
3016-1520-1200 = product model and rev. 5.xx
is the firmware revision.
The unit will append the '>' character if the command
is sucessfully processed.
Get IP address
{aaSi}
returns {aaSixxx.xxx.xxx.xxx}
(ethernet option)
where:
aa = unit address, range = 00 to 31, only used if interface
is RS485, otherwise omit
i = command code
xxx.xxx.xxx.xxx = IP address
Get subnet mask
{aaSs}
returns {Ssxxx.xxx.xxx.xxx}
(ethernet option)
where xxx.xxx.xxx.xxx = subnet mask
3016-1520-1200 Manual_Rev. B
Page 9. 12/11/19