1.0 General
1.1 Equipment Description
The 3016-1520-1200 Downconverter converts 15 to 20 GHz to 1200 ± 50 MHz in 125 kHz steps (1 kHz opt-
X1008). The 15 to 20 GHz is first converted to 7.0 GHz with an agile, high side LO and then to 1200 MHz to
obtain the wide tuning range. Synthesized local oscillators (LO) provide frequency selection. Multi-function
switches select the input frequency, gain, and other parameters. Front panel LEDs provide indication of DC
power, PLL alarm or Remote operation. Gain is adjustable manually (MGC) over a +10 to +30 dB range. The
frequency and gain are remotely selectable. Parameter selection and frequency and gain settings appear on the
LCD display. Connectors are SMA female for the RF, and BNC female for the IF and external 10 MHz
reference input and output. Other connector options are available. It is powered by a 100-240 ±10%VAC
power supply, and is in a 1 3/4” X 19” X 18” rack mount chassis.
MENU
EXECUTE
MODEL 3016
C
ROSS
T
ECHNOLOGIES INC.
REMOTE
POWER
ALARM
DOWNCONVERTER
F=19123.125
G=+10 REF = INT
FRONT
AC
GND
J3
J10
J18
J2
RF IN
10 MHZ REF
OUTPUT
10 MHZ
EXT REF
INPUT
MONITOR
AND
CONTROL
J5
RF OUT
1
5
2
3
4
6
7
8
9
J20
REAR
FIGURE 1.1 Model 3016-1520-1200 Front and Rear Panels
7.0 GHz
BP
var
atten
1200
MHz
OUT
8200
MHz
1300 MHz
LP
22.0
TO
27.0
GHz
15
to
20
GHz
IN
SW,PLL,ATT,VCC CONTROL
M&C
CONTROLLER
19123.125 MHz
G=10 REF=INT
EXT
10MHz
INT 10MHz
10MHz
TO
VCOs
3016-1520-1200
Block Diagram
15 to 20 GHz
BP
FIGURE 1.2 Model 3016-1520-1200 Downconverter Block Diagram
3016-1520-1200 Manual_Rev. B