C) Commands
Table 1.2 lists the commands for the 2582-122 and briefly describes them. After a command is
sent the 2582-122 sends a return “>” indicating the command has been received and executed.
General Command Format
- The general command format is {aaCND...}, where:
{ = start byte
aa = address of unit (only used if in RS-485 mode)
C = 1 character, either C (command) or S (status)
N = 1-digit command or status number, 1 through 9
D = 1 character or more of data (depends on command)
} = stop byte
*
PLEASE NOTE: The two character {aa} prefix, in the table below, should be used
ONLY when RS-422/RS-485, (OPTION-Q), is selected.
Table 1.2 2582-122 Commands
Table 1.2 2582-122 Commands
Command
Syntax*
Description
Set CH1 Status and Mode
{aaC1xy}
where:
• x = 0; CH1 Protected
• x = 1; CH1 Unprotected
• y = 0; set CH1 to AUTO mode
• y = 1; switch BACK-UP to CH1
Set CH2 Status and Mode
{aaC2xy}
where:
• x = 0; CH2 Protected
• x = 1; CH2 Unprotected
• y = 0; set CH2 to AUTO mode
• y = 1; switch BACK-UP to CH2
Set Min. Auto Switching Mode {aaC5x}
where:
• x = 0; Minimum Auto Switching DISABLED
• x = 1; Minimum Auto Switching ENABLED
Restore Switch Position
{aaC6x}
where:
• x = 1; Restore Switch Position after the switch position
changed in Minimum Auto Switching mode
All external units (1, 2, and backup) can be controlled remotely via the 2582 switch. Converters to be
controlled must be in RS-232 remote mode. Simply enter a prefix of *1, *2, or *5 for units 1, 2, or backup,
respectively, before entering the corresponding unit’s status request or command. For example, to send a status
command of S1 to converter #1 you would enter {aa*1S1}, where the address, aa, would only be necessary if
the 2582 were in RS-485 mode. Any returned status will also be prefixed with a *1, *2, or *5.