2.4
Installation / Operation
2.4.1
Installing and Operating the 2582-122, Switch Section
1. Connect Converters (CH1, CH2, BU) to respective channels on the 2582-122 (Figure 2.1).
2. Connect Alarm/Control cables from Converters to respective monitors on the 2582-122 (Figure 2.1).
3. Connect two 100-240 ± 10% VAC, 47 - 63 Hz power cords to AC A and AC B on the back panel
(Figure 2.1).
4. Set which unit(s) you wish to protect and the mode for each unit (See Section 2.5 Menu Settings).
5. Be sure DS1 & DS2 (green, DC Power) are on and DS3 to DS8 (red, Alarm) are off (Figure 2.2).
6. AC Fuses
-
The fuses are 5 mm X 20 mm, 2 amp slow blow (Type T) and are inserted in the far slot in
the drawer below the AC inputs as shown in Figure 2.3. There is a spare fuse in the near slot. If a fuse
continues to open, the corresponding power supply is most likely defective.
FUSE DRAWER
SPARE FUSE DRAWER
AC Fuse - 2 amp slow blow (Type T),
5 mm X 20 mm
~
INPUT
100-240 VAC
47-63 Hz
2A MAX
FUSE
TYPE T 2A
250 VOLT
FOR 100 - 240 V~
~
FIGURE 2.3 Fuse Location and Spare Fuse