Cross Technologies 2582-122 Instruction Manual Download Page 1

Instruction Manual   

                     

Model 2582-122

Switch

January 2022   Rev B

MENU

EXECUTE

MODEL 2582

C

ROSS 

T

ECHNOLOGIES INC.

PROT
MODE

1

BU SW

ALARMS

SWITCH

BU

2

1

2

1

2

ONLINE / OFFLINE

POWER

STATUS

1

BU

2

P
A

P
M

2
M

Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., 

but may be reproduced or duplicated without the prior permission of Cross Technologies, Inc. 

for purposes of operating the equipment.

When ordering parts from Cross Technologies, Inc., be sure to include the equipment model number, 
equipment serial number, and a description of the part.

C

ROSS 

T

ECHNOLOGIES, INC.

6170 Shiloh Road

Alpharetta, Georgia 30005

(770) 886-8005

FAX (770) 886-7964

Toll Free 888-900-5588

WEB www.crosstechnologies.com 

E-MAIL [email protected]

Summary of Contents for 2582-122

Page 1: ...echnologies Inc but may be reproduced or duplicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment When ordering parts from Cross Technologies Inc be sure to include the equipment model number equipment serial number and a description of the part CROSS TECHNOLOGIES INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free ...

Page 2: ... Cross Technologies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subassemblies or entire assemblies Cross Technologies Inc shall not be liable for any special indirect or consequential damages This warranty does not cover parts or equipment which have been subject to misuse negligence or accident by the customer during use All s...

Page 3: ... each on line converter Alarms are contact closures to ground Status of the 2582 122 is via a serial data stream and a contact closure to ground on alarm All settings are stored in nonvolatile ROM and on power up the 2582 122 polls all units Manual Select is controlled by the multi function switches on the front panel LEDs indicate alarm and switch conditions The unit is powered by redundant power...

Page 4: ...ators Manual Selection Push button switches Remote Selection RS 232C RS422 485 option Q 9600 baud Power Green LEDs Alarms Red LEDs Online Offline Green LEDs Other RF Connectors Type F female Option BNC 75 or 50 Ohm IF Connectors BNC female Option BNC 50 Ohm Alarm Remote Connectors DB9 female Size 19 inch 1RU standard chassis 1 75 high X 16 0 deep Power 100 240 10 VAC 47 63 Hz 45 watts max Redundan...

Page 5: ...OTE The two character aa prefix in the table below should be used ONLY when RS 422 RS 485 OPTION Q is selected TABLE 1 1 2582 122 Status Requests TABLE 1 1 2582 122 Status Requests TABLE 1 1 2582 122 Status Requests Command Syntax Description Command Status aaS1 Returns aaS1bcdefghi where b BACK UP Status 0 Normal no channels backed up 1 CH1 is currently backed up 2 CH2 is currently backed up c CH...

Page 6: ... set CH1 to AUTO mode y 1 switch BACK UP to CH1 Set CH2 Status and Mode aaC2xy where x 0 CH2 Protected x 1 CH2 Unprotected y 0 set CH2 to AUTO mode y 1 switch BACK UP to CH2 Set Min Auto Switching Mode aaC5x where x 0 Minimum Auto Switching DISABLED x 1 Minimum Auto Switching ENABLED Restore Switch Position aaC6x where x 1 Restore Switch Position after the switch position changed in Minimum Auto S...

Page 7: ...ing Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of circuits could have on over current protection and supply wiring Appropriate consideration of equipment name plate rating should be used when addressing this concern E Reliable Earthing Reliable earthing of rack mounted equipment should be maintained Particular attention sh...

Page 8: ... deep chassis Two redundant switching 12 24 5 VDC power supplies provide power for the assembly The 2582 122 can be secured to a rack using the 4 holes on the front panel Figure 2 0 shows how the 2582 122 is assembled CONTROLLER PCB POWER SUPPLY B POWER SUPPLY A IF RF SWITCH PCBS FIGURE 2 0 2582 122 Mechanical Assembly 2582 122 Manual Rev B Page 8 1 24 22 ...

Page 9: ...he output from the converter BNC female 75Ω RF SIGNALS J11 J12 J21 J22 J1 J2 Signals to from Unit 1 Unit 2 and the Backup Unit CONV goes to the up down converter IN OUT is the input to or the output from the converter BNC female 75Ω J11 J15 J13 A B A B GND ETHERNET FIGURE 2 1 2582 122 Rear Panel I Oʼs TABLE 2 1 SWITCH Pinouts RS 232C 422 485 TABLE 2 1 SWITCH Pinouts RS 232C 422 485 Pin Function 1 ...

Page 10: ...in the Menu items when in program mode Does not function in the normal display mode S3 HORIZ TOGGLE Horizontal toggle switch that controls which values are being adjusted Does not function in the normal display mode MENU EXECUTE PROT MODE 1 BU SW ALARMS BU 2 1 2 1 2 ONLINE OFFLINE POWER STATUS 1 BU 2 P A P M 2 M DS3 DS4 DS7 DS8 ALARM LEDs Red LEDs indicate alarm state for Unit 1 Unit 2 Back Up Uni...

Page 11: ...ach unit See Section 2 5 Menu Settings 5 Be sure DS1 DS2 green DC Power are on and DS3 to DS8 red Alarm are off Figure 2 2 6 AC Fuses The fuses are 5 mm X 20 mm 2 amp slow blow Type T and are inserted in the far slot in the drawer below the AC inputs as shown in Figure 2 3 There is a spare fuse in the near slot If a fuse continues to open the corresponding power supply is most likely defective FUS...

Page 12: ...Menu 6 Set RS 485 address Menu 7 Set Minimum Auto Switching Mode ON and OFF Menu 8 Restore Switch Position in Minimum Auto Switching mode Save Menu When R is selected or when get to the end Alarm indications appear on the LEDs see figure 2 2 All program changes must start with the operation of the Menu Execute switch and must also end with the operation of the Menu Execute switch verified by the S...

Page 13: ...nit is now operational and ready for any changes the operator may desire 2 5 3 Control Switches 1 Menu Execute Any change to the programming of the unit must be initiated by pressing the Menu Execute switch and completed by pressing the Menu Execute switch 2 Horizontal Switch This switch is mounted so its movement is horizontal and moves the cursor left or right 3 Vertical Switch This switch is mo...

Page 14: ...485 Address Menu 7 Set Min Auto Switching Menu 8 Restore Switch Save When R is selected from any above menu or at the end SCROLL SCROLL PUSH BUTTON SAVE SETTINGS Y N SCROLL PUSH BUTTON R RS 485 OFF SCROLL SCROLL PUSH BUTTON R ADDRESS 00 SCROLL SCROLL PUSH BUTTON R PROT MODE STATUS 1 BU 2 P A P A A CH2 _ Protected R CH1 _ Auto R CH2 _ Auto R 3 P A 4 P A Minimum Auto R Swiching ON SCROLL SCROLL PUSH...

Page 15: ... that caused the unit to switch has been cleared The main display will show an H under the BU MODE after an alarm causes the switch to change states while in the Minimum Auto Switching mode The unit can be restored to the normal state via a front panel restore command or an M C restore command The front panel restore switch menu appears after the Minimum Auto Switching mode ON OFF menu only if the...

Page 16: ...HNOLOGIES INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com 2582 122 Manual Rev B Page 16 1 24 22 ...