background image

B) Status Requests 

Table 1.1 lists the status requests for the 2017-95 and briefly describes them.

*

 PLEASE NOTE: The two character {aa}(00-31) prefix, in the table below, 

    should be used ONLY when RS-485, (OPTION-Q), is selected.

.

Table  1.1  2017-93  Status  Reequests

Re

quests

Command 

Syntax*

Description

Command Status 

{aaS1} 

Returns {aaS1bbbbccccddddeeeffLMNOP} where:
• bbbb = Tx frequency
• cccc = Rx frequency
• dddd = Tx gain (-100 to 300)
• eee = Rx gain (000 to 500)
• ff = Tx input level (10 to 40)
• L = 0 - non-inverted Receiver;  L = 1 - inverted
• M = 0 - Receiver synth alarm
• N = 0 - Transmitter synth alarm
• O = 0 - Summary alarm
• P = 0 - Transmit signal disabled (muted)

External 10MHz

{aaS2} 

Returns {aaS2bcd} where:
• b = 1 - External 10MHz selected
• c = 1 - 10MHz inserted on upconverter RF (J5)
• d = 1 - 10MHz inserted on downconverter RF (J2)

LNB Current

{aaS3} 

Returns {aaS3bb} where:
• bb = LNB current, range 00 to 50 (0 to 500 ma)

SSPB Current

{aaS4}

Returns {aaS4bbb} where:
• bbb = SSPB current, range 000 to 250 (0 to 2500 ma)

* PLEASE NOTE: The Address (aa) should only be used when RS-485 is selected (option -Q ONLY)

2017-93 Manual, Rev D

 

Page 6

     

         05/19/10

Summary of Contents for 2017-93

Page 1: ...Technologies Inc but may be reproduced or duplicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment Printed in USA When ordering parts from Cross Techno...

Page 2: ...o customer Cross Technologies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subassemblies or entire assemblies Cross Technologies I...

Page 3: ...and Type F female for RF LNB 24 VDC down and SSPB 24 VDC up are inserted on the RF lines when the corresponding rear panel fuse is installed The 10 MHz reference is also inserted on the RF lines A hi...

Page 4: ...ED Up Mute Yellow LED Remote Yellow LED RS232C 9600 baud RS485 option Q Other RF Connectors Type F female see Table 2 2 for connector options IF Connectors BNC female see Table 2 2 for connector optio...

Page 5: ...6 7 8 9 Female DB 9 PC Com Port Male DB 9 2015 16 17 M C Port M C Cable Diagram Cross Technologies Frequency Converters RX RX TX TX DTR SG DSR RTS CTS SG Connector Rear panel DB 9 male J10 Pinouts Pin...

Page 6: ...0 to 500 ff Tx input level 10 to 40 L 0 non inverted Receiver L 1 inverted M 0 Receiver synth alarm N 0 Transmitter synth alarm O 0 Summary alarm P 0 Transmit signal disabled muted External 10MHz aaS2...

Page 7: ...Receiver Frequency aaC2xxxx where xxxx 4 characters Range 0950 to 1525 MHz Set Transmit Gain aaC3xxxx where xxxx 3 or 4 characters Range 100 to 300 10 0 dB to 30 0 dB in 1 dB steps Set Receiver Gain a...

Page 8: ...equipment is not compromised Additional space between unit may be required E Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect...

Page 9: ...16 inch deep chassis A switching 12 5 24 VDC power supply provides power for the assemblies The 2017 can be secured to a rack using the 4 holes on the front panel Figure 2 0 shows how the 2017 is asse...

Page 10: ...1 SSPB FUSE 3A Fast Blo 1 4 Fuse Installing fuse places 24VDC 2 5 amp max on the RF OUT J5 center pin J1 10MHZ REF OUTPUT 10 MHz reference output 0 3 dBm 75 BNC female J4 IF IN 70 MHz input 10 to 40 d...

Page 11: ...into Program mode and press again to execute any changes DS3 ALARM LED Red LED indicates downconverter alarm DS6 POWER LED Green LED indicates presence of DC DS1 REMOTE LED Yellow LED indicates remot...

Page 12: ...the 2017 Downconverter Section 1 Connect a 70 dBm to 20 dBm signal to RF In J2 Figure 2 1 2 Connect the IF OUT J1 to the external equipment 3 Connect 90 260 VAC 47 63 Hz to AC1 on the back panel 4 Se...

Page 13: ...FUSE DRAWER SPARE FUSE DRAWER AC Fuse 2 amp slow blow Type T 5 mm X 20 mm Figure 2 3 Fuse Location and Spare Fuse 2017 93 Manual Rev D Page 13 05 19 10...

Page 14: ...Ref Menu 10 Upconverter Reference Out Menu 11 Downconverter Reference Out Menu 12 Set RS 485 mode option Q Menu 13 Set RS 485 address option Q Menu 14 View PCB Temperature Menu 15 View LNB and SSPB Cu...

Page 15: ...rator may desire 2 5 3 Control Switches 1 Menu Execute Any change to the programming of the unit must be initiated by pressing the Menu Execute switch and completed by pressing the Menu Execute switch...

Page 16: ...play to U P F 1 2 5 0 R By using the horizontal rocker switch the cursor can be moved left or right U P F 1 2 5 0 R NOTE CHANGES DO NOT TAKE PLACE ON FREQUENCY UNTIL YOU GO TO THE SAVE MENU AND INDICA...

Page 17: ...accurately as possible U P I N L V L 2 0 R Pressing the Up Down switch to change the level in 1 dB steps and then push the Menu Execute switch to get to the Gain setting U P G 2 0 0 R By using the hor...

Page 18: ...l toggle the display digit selected until you have the desired gain NOTE THE GAIN WILL BE CHANGED AS YOU ADJUST THE NUMBERS HOWEVER THE VALUE WILL NOT BE STORED UNTIL YOU INDICATE YES IN THE SAVE SETT...

Page 19: ...current and SSPB current Save Settings At the end or when R is selected from any of the above menus SAVE SETTINGS Y N SCROLL PUSH BUTTON UP F 1450 SCROLL SCROLL PUSH BUTTON R SCROLL SCROLL PUSH BUTTO...

Page 20: ...S INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com Printed in USA 2017 93 Manual Rev D...

Reviews: