MODEL 2016-26 Downconverter
1.0 General
1.1 Equipment Description
The 2016-26 Downconverter converts 2000 to 2500 MHz to 140 ± 36 MHz in 1 MHz steps with low group
delay and flat frequency response. Synthesized local oscillators (LO) provide frequency selection. Multi-
function push button switches select the RF frequency and gain. Front panel LEDs provide indication of DC
power (green), remote operation (yellow), and PLL alarm (red). Variable attenuators for the RF input provide a
gain range of 0 to +50 dB as adjusted by the front panel multi-function pushbutton switches. Frequency and
gain settings appear on the LCD display. Connectors are BNC female for RF, IF and optional 10 MHz Input and
Output signals (
option E
). The unit is powered by a 100-240 ±10% VAC power supply, and housed in a 1 3/4”
X 19“ X 16” rack mount chassis.
MENU
EXECUTE
MODEL 2016
F = 2050 G = +10.0
POWER
ALARM
DOWNCONVERTER
REMOTE
C
ROSS
T
ECHNOLOGIES INC.
FRONT PANEL
AC
GND
J3
J10
J18
10 MHZ REF
10 MHZ
AND
MONITOR
EXT REF
CONTROL
J1
IF OUT
OUTPUT
INPUT
1
5 2
3
4
6
7
8
9
J2
RF IN
REAR PANEL
FIGURE 1.1 Model 2016-26 Front and Rear Panels
140
MHz
OUT
2.0
to
2.5
GHz
IN
CONTROLLER
F=2250 G=+10
EXT
10 MHz
*
INT/EXT
10 MHz
INT
10 MHz
VAR
ATT
Block Diagram
FIGURE 1.2 Model 2016-26 Downconverter Block Diagrams
2016-26 Manual, Rev. A
Page 3
2/2/09