background image

2.5  Menu Settings

2.5.1  Functions - This  section  describes operation of the front panel controls.  There are three operator 
switches, the LCD display and alarm indicator LEDs.  All  functions for the equipment are controlled by these 
components.  The functions are (see Figure 2.5):

Power Up
Normal Display

Menu 1 Frequency in MHz
Menu 2 Gain (0 to +50, 1dB steps)
Menu 3 Set Unit to Remote Operation
Menu 4 Select External 10 MHz Ref (option E)
Menu 5 Select Reference Out (option E)

Menu 6 Set Remote mode (option Q)
Menu 7 Set RS-485 address (option Q)
Menu 8 View PCB Temperature (option T)

Menu 9 View LNB Current (option L)

Save Menu When go to end

Alarm indications appear on the LEDs (see figure 2.3).

All program changes must start with the operation of the Menu/Execute  switch and must also end with the 
operation of the Menu/Execute switch verified by the “Save Settings?” Menu.  If this sequence is not  followed, 
none of the changes will take effect. If programming is initiated and no operator action takes place for 
approximately 12 seconds (before the final press of the Menu/Execute switch) the display will revert to its 
previous status and you will need to start over.

2016-05A Manual, Rev A 

 

   Page 11

    

                  04/17/17

Summary of Contents for 2016-05A

Page 1: ...but may be reproduced or duplicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment When ordering parts from Cross Technologies Inc be sure to include th...

Page 2: ...ross Technologies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subassemblies or entire assemblies Cross Technologies Inc shall not...

Page 3: ...put and the optional external reference input and reference output and Type F female for the RF input A high stability 0 01ppm reference LNB 24 VDC 0 4 Amps power and 10 MHz reference includes a 10 MH...

Page 4: ...option H internal reference Frequency Step 1 0 MHz minimum 100 90 80 70 70 1MHz 100kHz 10kHz 1kHz 100 Hz dBC Hz Phase Noise Freq External 10 MHz level 0 dBm 3dB 75 option E Controls Indicators Freque...

Page 5: ...1 digit command or status number 1 through 9 D 1 character or more of data depends on command stop byte Table 1 1 2016 05A Command ds Commands Command Syntax Description Set Receiver Frequency aaC2xx...

Page 6: ...IA where bbbb Rx frequency bbbbbbb option X ccc Rx gain I 1 spectrum invert enabled A summary alarm 1 alarmed 0 normal 10MHz Ref Status aaS2 Returns S2ER where option E only E 1 external 10 MHz switch...

Page 7: ...h by 16 inch deep chassis A switching 12 24 5 VDC power supply provides power for the assemblies The 2016 05A can be secured to a rack using the 4 holes on the front panel Figure 2 1 shows how the 201...

Page 8: ...option L 1A Fast Blo 1 4 fuse Installing fuse places 24VDC 0 4 amps max on RF IN J2 center i FIGURE 2 2 2016 05A Rear Panel I Os TABLE 2 1 J1 10 2 1 J10 Pinouts RS 232C Pin Function 1 Not Used 2 Rx RS...

Page 9: ...icates downconverter alarm DS6 POWER LED Green LED indicates presence of DC power DS1 REMOTE LED Yellow LED indicates remote operation S2 VERT TOGGLE Vertical toggle switch that controls values in the...

Page 10: ...7 Option L only To insert LNB 24 VDC on the RF center pin install 0 5A fast blo fuse in F1 and check that DS8 lights yellow Figure 2 1 8 AC Fuse The fuse is a 5 mm X 20 mm 2 amp slow blow Type T and i...

Page 11: ...n Q Menu 7 Set RS 485 address option Q Menu 8 View PCB Temperature option T Menu 9 View LNB Current option L Save Menu When go to end Alarm indications appear on the LEDs see figure 2 3 All program ch...

Page 12: ...ay desire 2 5 3 Control Switches 1 Menu Execute Any change to the programming of the unit must be initiated by pressing the Menu Execute switch and completed by pressing the Menu Execute switch 2 Hori...

Page 13: ...frequency F 135 0 R Pressing the Up Down switch down will toggle the display to F 145 0 R By using the horizontal rocker switch the cursor can be moved left or right F 1450 R NOTE CHANGES DO NOT TAKE...

Page 14: ...on the cursor location G 15 0 R By using the horizontal rocker switch the cursor can be moved left or right Pressing the Up Down switch will toggle the display digit selected until you have the desir...

Page 15: ...to Remote Operation Menu 4 Select External 10 MHz Reference option E Menu 5 Select 10MHz Reference Out option E Menu 6 Set Remote Mode option Q Menu 7 Set RS 485 Address option Q Menu 8 View PCB temp...

Page 16: ...NOLOGIES INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com 2016 05A Manual Rev A Page 1...